To adjust the master crystal reference oscillator parameters: 
1.  First, check the factory default setting for the crystal reference parameter by 
typing 
cal  
2.  Note the value for “xo” in the cal factors table that is displayed. 
3.  At the XtermW command line, type: 
cal,set,xo,xx 
where xx is some value close to the original factory set value. 
4.  Use trial and error to determine the set point for the xo value to achieve the 
desired carrier frequency accuracy. 
 
To reset the XO tuning parameter to the factory setting: 
Power cycle the radio.  
5.4  Measure and Adjust Output Power 
 
Caution: Avoid unnecessary adjustments. Exercise caution when setting I 
and Q gain values as damage to the radio can occur if gains are set too 
high.  
The Locomotive radio is rated for 50W PEP. To achieve this power radios are pre-
calibrated at the factory. If additional tuning is required, use an appropriate method 
to determine PEP for a π/4-DQPSK signal. The CCDF function on the VSA is 
recommended for peak power measurement. Slowly increase/decrease I and Q gain 
levels from their nominal set point, as determined by issuing the command ‘cal’.  
A step of 100 points (for example, -250 to -150) is approximately equivalent to an 
increase of 2dB in power.  
To measure and adjust output power: 
1.  At the XtermW command line, begin transmitting a π/4-DQPSK signal by 
typing: 
dsp_mode,idle 
dsp,watchdog,off