Tyco Safety Products/Sensormatic UMUPPLUS ユーザーズマニュアル

ページ / 8
ULTRAPOST PLUS POWER PACK
8000-2642-02, Rev. A 04/20/99
INSTALLATION GUIDE
7
Figure 5. Connecting power
Specifications
Electrical
Power Supply
Primary Input: ......................... 100-120Vac or
220-240Vac
@ 50–60Hz
Primary Power Fuse: .............. 3A, 250V slo-blow
Current Draw: ......................... 2.0A peak
Input Power: ........................... <180W
Transmitter
Outputs:.................................. 2 ports (two antennas,
multiplexed)
Operating Frequency:............. 58 or 60kHz (±200Hz)
Transmit Burst Duration ......... 1.6ms
Transmit Current: ................... 16A peak
Burst Repetition Rate:
Based on 50Hz ac .................. 37.5Hz (Normal)
............................................... 75Hz (Validation)
Based on 60Hz ac .................. 45Hz (Normal)
............................................... 90Hz (Validation)
Receiver
Inputs:..................................... 2 ports (two antennas,
............................................... multiplexed)
Center Frequency:.................. 58 or 60kHz
Alarm
Alarm Relay Output ................ DPDT contacts
Contact Switching Current...... 1.0A max.
Contact Switching Voltage ..... 28V max.
Lamp/Audio Duration.............. 1–30 sec.
(1 sec. increments)
Environmental
Operating Temperature .......... 0° to 50°C (32°–122°F)
Relative Humidity ................... 0 to 90% non-condensing
AC
terminal
block
AC
terminal
block
Power select jumpers
JW1 and JW12
(behind metal cover)
Power select jumpers
JW1 and JW12
(behind metal cover)
AC power
knockout
AC power
knockout
European power pack