Park Air Systems Limited B63300HS ユーザーズマニュアル

ページ / 72
T6T 300 Watt VHF Transmitter
Page 131
Maintenance
(5)
At the Menu Bar, click on Serial Port and select either Com 1 or Com 2. The selection must
correspond to the port used to connect to the radio.
(6)
At the Menu Bar select Radio > Retrieve > All.
(7)
At the Menu Bar select Radio > Calibrate. The Confirm screen will then be displayed to remind
you that a dummy load must be connected before proceeding.
(8)
With the Confirm screen displayed and dummy load connected, select Yes to continue with the
calibrate routine. The Progress screen will then be displayed.
(9)
When the PA Control/PA loop has been calibrated the Progress screen disappears and the VFP
screen reappears showing a calibration complete message in the Status Information window.
(10) Gain access to the PA Control module and identify RV8 (see 
Fig 33
). From the drive assembly’s
front panel AM-Voice or AM-MSK Settings screen, select PTT On.
(11) From the Settings window of the VFP screen, note the RF power setting. Adjust RV8 until the
power meter reads this value. 
(12) From the drive assembly’s front panel AM-Voice or AM-MSK Settings screen select PTT Off,
then remove the power meter and dummy load. This completes the calibration routine.
(13) When there is no further requirement for using the VFP, exit the VFP software and disconnect
the radio from the PC and refit the bottom cover.
Location of RV8
Fig 33  Location of PA Control Module RV8
R130
R131
R125
C421
R135
RV8
CN4
R455
R456
424
R348
D24
R2
3
1
R3
8
2
R2
4
3
TP10