GENERAL INFORMATION
The ADEMCO 5828 and 5828V are wireless, bidirectional,
fixed-word, keypads that may be used in conjunction with
LYNX and VISTA series residential control panels. VISTA
systems require use of either a 5883 Transceiver (micro P/N
WAK5119-X, where X = 3 or higher), 6150RF Keypad/
Transceiver (PC board P/N SA6150RFAS-T3 or higher), or
6160RF Keypad/Transceiver. The 5828/5828V keypads are
not compatible with commercial control panels that have
three-digit zone numbers (e.g., VISTA128BP).
fixed-word, keypads that may be used in conjunction with
LYNX and VISTA series residential control panels. VISTA
systems require use of either a 5883 Transceiver (micro P/N
WAK5119-X, where X = 3 or higher), 6150RF Keypad/
Transceiver (PC board P/N SA6150RFAS-T3 or higher), or
6160RF Keypad/Transceiver. The 5828/5828V keypads are
not compatible with commercial control panels that have
three-digit zone numbers (e.g., VISTA128BP).
Both keypads provide:
•
•
Four programmable special function keys
•
Wall-mount plate for easy removal of the keypad and
battery replacement
battery replacement
•
Optional Desktop mount /AC adapter kit, ADEMCO
P/N 5828DM)
P/N 5828DM)
•
Battery-powered with 3-AA batteries
The 5828V keypad additionally provides:
•
•
Memo/Message center
•
Voice Response – system status, zone information, and
alarms with zone information
alarms with zone information
•
Stored Message LED indication
•
Built-in microphone and speaker
NOTES:
•
•
The 5828/5828V cannot be used as the primary system
keypad, and may not be used to program or test any
security system. All systems require a hardwired
keypad (or Compass Downloader) to do so. Once
programmed, the 5828/5828V can be used to initiate all
common functions of a fixed English keypad.
keypad, and may not be used to program or test any
security system. All systems require a hardwired
keypad (or Compass Downloader) to do so. Once
programmed, the 5828/5828V can be used to initiate all
common functions of a fixed English keypad.
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
#
ARMED
READY
5828-00-001-V0
A
B
C
D
5828 Keypad with Front Cover Removed
5828V
-00-002-V0
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
#
MESSAGE
MIC
ARMED
READY
RECORD
VOLUME
PLA
Y
ST
A
TUS
FUNCTION
VOICE
D
C
B
A
5828V Keypad with Front Cover Removed
Operation (See NOTE below)
1.
Battery-Powered Operation: When powered by
battery, the keypad activates when any key is
pressed. When the
battery, the keypad activates when any key is
pressed. When the
[✱] key is pressed, the keypad
sends a system status request, and displays and/or
annunciates the present status transmitted by the
system.
annunciates the present status transmitted by the
system.
2.
AC-Powered Operation: When powered by AC, the
keypad remains active at all times. Any change in
system status will cause the display to automatically
turn on (if blank) and display/annunciate the new
status.
keypad remains active at all times. Any change in
system status will cause the display to automatically
turn on (if blank) and display/annunciate the new
status.
If AC power is lost, the keypad will revert to battery-powered
operation until AC power is restored and a new status
request is made ([✱] key).
operation until AC power is restored and a new status
request is made ([✱] key).
NOTE: Whether the unit is powered by battery or AC, the
5828/5828V may take up to 5 seconds to display and/or
annunciate the new status after pressing the [✱] key.
5828/5828V may take up to 5 seconds to display and/or
annunciate the new status after pressing the [✱] key.
WALL MOUNTING
Before mounting the 5828 & 5828V permanently, determine
a good RF location as follows:
a good RF location as follows:
• If interfacing to a LYNX panel, try communicating with
the panel from different locations.
• If interfacing to a VISTA panel, perform a Go/No Go test
from the panel. Refer to the Go/No Go test mode in the
Installation and Setup Guide for the panel.
Installation and Setup Guide for the panel.
Avoid mounting locations on or near large metal objects,
since these can decrease the transmission range or block
transmissions.
• Secure the mounting plate to the wall, using proper sized
since these can decrease the transmission range or block
transmissions.
• Secure the mounting plate to the wall, using proper sized
hardware through the six mounting holes.
• Plug the cord from the optional power pack into the
keypad’s DC input connector, and route the wires
through the wire guides on the back of the keypad.
through the wire guides on the back of the keypad.
• Position the keypad over the mounting plate and slide
down, engaging the four retaining clips on the plate with
the receptacles on the keypad.
the receptacles on the keypad.
DESKTOP MOUNTING
For full portability, the keypad may be placed in any conven-
ient, RF-suitable location and operated in its battery-
powered mode, or near an AC outlet to be powered by the
optional Power Pack/Desktop Mounting Kit, ADEMCO P/N
5828DM.
ient, RF-suitable location and operated in its battery-
powered mode, or near an AC outlet to be powered by the
optional Power Pack/Desktop Mounting Kit, ADEMCO P/N
5828DM.
BATTERY INSTALLATION OR REPLACEMENT
CAUTION: Remove the AC/DC power connector from the
keypad (if applicable), before attempting to install or replace
the batteries.
keypad (if applicable), before attempting to install or replace
the batteries.
1.
Separate the keypad from its mounting plate by
sliding the keypad up and away from the mounting
plate.
sliding the keypad up and away from the mounting
plate.
2.
Open the battery compartment door to expose the
batteries.