Honeywell International Inc. 8DL5890PI-1 ユーザーズマニュアル

ページ / 2
 
N5987-2V1  10/99  Rev. B 
$'(0&23,
3$66,9(,1)5$5('027,21'(7(&72575$160,77(5
 
INSTALLATION INSTRUCTIONS 
 
GENERAL INFORMATION 
The 5890PI Passive Infrared Motion 
Detector/Transmitter is a battery-operated 
wireless device intended for use as part of a 
5800 series wireless alarm system.  
Designed for use in commercial and residential 
installations, the 5890PI is a wall-mounted unit 
with a standard lens that provides wide-angle 
protection up to a range of 35 ft (10.6m). For 
best coverage, mount the detector so that the 
likely direction of intruder motion is across  the 
pattern.  
When installed per the guidelines, the Split-
Zone Optics technology in the 5890PI provides 
reasonable false alarm protection against pets 
and other animals up to 40 lbs. 
This document provides installation instructions 
for the 5890PI, but the installer must be familiar 
with the installation instructions for the 5800 
Wireless Alarm System with which the 5890PI 
is intended to be used. 
 
FEATURES 
• Split-Zone Optics provides pet immunity 
against animals up to 40 lbs. 
•  Wireless operation for fast installation. 
• Dual-element pyroelectric sensor provides 
positive protection while minimizing false 
alarms. 
•  Alternate-polarity pulse count option offers 
greater stability in adverse environments. 
•  Provision to turn LED on while Walk Testing 
(LED is turned off after testing). 
• Tamper-protected cover; unit transmits 
message if cover is removed. 
•  Wall or corner mounting options. 
 
SYSTEM DESCRIPTION 
Optical System 
Uses efficiently designed Fresnel lenses with 
Split-Zone Optics. 
Radio Transmitter 
The built-in transmitter serves only as the 
communication link to the alarm system's 
Receiver/Control, and can send alarm, tamper, 
supervisory, and battery status messages to 
the system's receiver/control. The transmitter is 
not used for detection purposes. Each detector 
has a unique ID code permanently assigned at 
the factory. You must enroll this ID into the 
control system at the time of installation. This 
allows each detector used in the system to be 
uniquely identified. You must program the 
control to enroll the 5890PI as an "RF" type unit 
(i.e., supervised RF).  
To conserve battery life during normal 
operation, no more than one transmission 
sequence will occur within a 3-minute period. 
There is no such time restriction in Test mode. 
Alternate-Polarity Pulse Count 
Two jumper-selectable detection response 
modes are provided: 
Instant response
 (Pulse 
Count OFF) and 
Alternate-Polarity Pulse Count 
(Pulse Count ON). With Pulse Count OFF, any 
detected change in infrared energy triggers an 
immediate alarm signal. This mode is 
recommended when the detector is used to 
monitor a narrow hallway where coverage is 
provided by only a single zone. Use the Pulse 
Count ON mode when the detector is installed 
in areas where periodic changes in infrared 
energy levels are normal (for example, where 
forced-air heating ducts are present). In this 
mode, at least two changes in infrared energy 
must be detected within a short period before 
an alarm is triggered. 
Important Note: 
For pet immune 
applications, Pulse Count ON is 
recommended.
 
 
SPECIFICATIONS 
Pet Immune 
Lens
35 ft x 45 ft (10.6m x 13.7m). 
 
30 zones (8 long, 7 over 7 inter-
 
mediate, 4 over 4 short-range). 
Pulse Count:  Installer-selectable On/Off link. 
Detectable 
Walk Rate:  
0.5–10 ft/Sec (0.15–1.5m/Sec). 
Mtg. Height:  7.0 ft recommended (2.1m),  
 
but may be mounted at other 
 
heights (see Table 1). 
Walk Test 
Indicator: 
Red LED with Test/Normal 
 (disable) 
link. 
Batteries: 
Two 3-volt Lithium batteries. 
Use only ADEMCO No. 466, 
Duracell DL123A, Panasonic 
CR123A, Sanyo CR123A, or 
Varta CR123A. 
0perating 
Temperature: 
32°F – 122°F (0°C - 50°C). 
Operating 
Humidity:
 
Up to 95% RH (max.), non- 
 condensing. 
Dimensions:  2-11/16"W x 5"H x 1-7/8"D 
 
68mm x 127mm x 48mm. 
ALTERNATE 
COUNT POLARITY
EACH ZONE CONSISTS
OF 2 FIELDS
0
25'
(7.6m)
25'
(7.6m)
10'
(3m)
20'
(6m)
30'
(9m)
35'
(10.6m)
0
7.5'
(2.3m)
0
10'
(3m)
20'
(6m)
30'
(9m)
35'
(10.6m)
 
Figure 1. Protection Pattern 
 
 
BATTERY INSTALLATION 
1.  Remove front cover by inserting a large 
screwdriver blade (or small coin) in groove 
between cover and base at the location 
shown in Figure 2; rotate blade to override 
snap fit, then lift cover off. 
2.  Observing correct polarity, install the two 
Lithium batteries (supplied) into the battery 
holders,  as shown in Figure 5. Make sure 
the batteries are firmly seated. 
3.  Replace the cover (snap fit). 
Battery Caution 
Risk of fire, explosion, and burns. Do not 
recharge, disassemble, heat above 100°C, or 
incinerate. Dispose of used batteries promptly. 
Keep away from children. 
Programming Note: If you have not 
programmed the detector’s ID into the 
system (i.e., this is an initial detector 
installation), refer to the 
PROGRAMMING 
section below and perform the ID enrolling 
procedure before mounting or testing the 
detector. 
 
PROGRAMMING 
You must enroll the detector’s ID during 
installation of the system. You should 
program the 5890PI as an “RF” type unit 
(i.e., supervised RF), and the "Loop" 
number as "1."
  
To program the detector, place the LED jumper 
in the TEST position (see Figure 5), the Pulse 
Count jumper in the OFF position, batteries 
installed and cover on. Temporarily cover the 
lens (a cloth will do) to prevent any activation 
by the detector.  
When prompted for the device’s serial number, 
you may either manually enter it or transmit 
from the unit (remove the cloth cover and 
motion your hand over the lens to activate the 
detector, press the tamper switch, etc.).  
Refer 
to the control panel installation instructions for 
programming details.  
Return LED jumper to the NORMAL position 
after it is enrolled in the control.
 
 
INSTALLATION 
Installation Hints 
• 
Do not install where the detector is exposed 
to direct sunlight or directly above strong 
sources of heat.
 
• 
Make sure the detection area does not have 
obstructions (curtains, screens, large pieces 
of furniture, plants, etc.) that may block the 
pattern of coverage. 
• 
Avoid locating a unit in areas that contain 
objects likely to produce a rapid change in 
temperature, such as central heating, 
radiators, or ducts (or heaters of any kind), 
air conditioners, open flame, etc. 
  Do not mount on an unstable surface. 
IMPORTANT:  For installation with pets, be 
sure to follow the guidelines described in 
Table 2.