Installation Instructions 
 
 
 
The SiXGB is a wireless glassbreak detector intended for use with Honeywell controls that support SiX™ Series 
devices. 
Mounting Guidelines
 
The SiXGB can be mounted on the 
wall or on the ceiling: 
•  within 7.6 m (25 feet) of the 
protected glass 
•  within clear view of the protected 
glass 
•  at least 2 m (6.5 feet) from the floor 
•  at least 1 m (3.3 feet) from forced 
air ducts 
•  at least 1 m (3.3 feet) from sirens or 
bells greater than 5 cm (2 inches) in 
diameter 
•  between the protected glass and 
any heavy window coverings 
•  when heavy window coverings are 
present, the detector can be 
mounted on the window frame 
•  Avoid mounting the detector on the 
same wall as the protected glass, 
on free-standing posts or pillars, or 
in rooms with noisy equipment (air 
compressors, bells, power tools, 
etc.), if this equipment is operated 
when the detector is armed. 
> 2.0m (6.5') 
Optimal
Satisfactory
No
> 1m 
(3.3') 
< 7.6m (25') 
> 1m 
(3.3') 
> 5 cm 
(2”) Diameter
 
R
F
6
G
B-
W
a
ll
M
o
u
n
t
W all Mount ( To pView)
Do  NOT mo unt o n 
c o lumns, po sts o r po le s.
Glass
  
Ceiling Mount ( Side View)
RF6GB-Ceiling Mo unt
Ceiling
Glass
Flo o r
 
To remove the mounting bracket: 
Turn the top of the detector 15 degrees counter-
clockwise and separate the mounting bracket. 
NOTE: Before mounting the device permanently, 
conduct Go/No Go tests (see controller’s 
instructions) to verify adequate signal strength and 
adjust the device location and orientation as 
necessary. 
The rear tamper plate MUST be mounted to a stud, 
solid wood, or with a robust wall anchor. 
 