5.4.3 Mounting sensor unit
 CAUTION
Risk of injury from rotating machine parts!
When installing the sensor unit while the machine is running, 
there is a risk of serious injury caused by exposed, moving machine 
parts.
 
» Do not remove any guards on the machine.
 
»  Always adhere to the safety instructions for work on running 
machinery.
•  Install the sensor unit at the location with the best possible radio 
reception. 
•  Drill two mounting holes. For the drill pattern, refer to the fixing 
tabs on the housing in the dimensional drawing in chapter 3 
“Technical data”.
•  Secure the sensor unit with two bolts to the machine.
Note
It is also possible to use one sensor unit to monitor two separate 
machines of a machine train, for example in cases where only the 
bearing at the coupling side of the motor and the pump are to be 
monitored. It is, however, not possible to monitor two separate 
machine trains with a single sensor unit.
•  Document the location of installation of the sensor unit in the 
measurement location report: Each sensor unit is supplied with 
an adhesive label on which the MAC address of the sensor unit 
is printed. Remove this label and stick it to the measurement 
location report beside the name of the respective machine or 
machine train.
Installation and commissioning
Adhere the MAC address 
of the sensor unit on the 
measurement location 
report.