4.2  AutoLink 
Some receivers utilize AutoLink to synchronize the ID Code between the transmitter and receiver. This allows 
a quick and easy method to replace a transmitter with a spare (see 
). 
4.3  Power Supply 
Standard operating power for the receiver is 12 VDC automotive power, but they will operate from 12 to 24 
VDC. 
4.4  Receiver Diagnostics 
The receiver assembly monitors and indicates its status on a continuous basis. The diagnostics are presented 
in a simple, easy to understand format. 
4.5  Safety Features 
Controlling industrial and commercial equipment requires that the wireless control system be reliable with 
built-in safety features. These receivers offer a maintained link system. This means in order for the system to 
operate, the signal from the transmitter must be continuously received by the receiver. Loss of the 
transmitter signal causes the safety system to remove all commands from the system and open the safety 
relay contact. Each transmission goes through several checks to ensure the receiving information is error 
free. Millions of combinations of frequencies and address codes mean that no two systems will ever be 
produced with the same frequency and address code. 
The safety relay is controlled by the microprocessor and by a hardware circuit to ensure operation even in 
the event of a circuit failure. During normal operations, this relay is closed (activated). If, for any reason, valid 
data is not being received, this relay opens.