Computime Limited AAHZT21 ユーザーズマニュアル
July 5, 2012
Page 10 of 49
66 8003 002-7
3.3 Parameters / specifications
Temperature display range
2-digit display – no limit
Guest control range*
65 – 90 ºF / 18 – 32 ºC ; configurable through
service device
service device
HVAC control types
Standard H/C; heat pump
Input voltage
12-24V AC
15-24 V DC
Output logic
Input voltage level
Outputs
W/W2 – Heating
Y/W2 – Cooling / compressor
G1 – Fan 1
G2 – Fan 2
G3 – Fan 3
RV – Reversing valve
Y/W2 – Cooling / compressor
G1 – Fan 1
G2 – Fan 2
G3 – Fan 3
RV – Reversing valve
Inputs
Door switch – 1 exterior / 1 interior
Motion sensor/card switch I/O
Service connector (programming)
Motion sensor/card switch I/O
Service connector (programming)
Temperature sensor*
Integrated in thermostat
Option: remote temperature sensor that connects
directly to the thermostat controller
directly to the thermostat controller
RF signals
ZigBee 2006
Lock to thermostat:
•
Door open – staff card
•
Door open – guest card (includes check-out
date/time, suite rooms and first time use)
date/time, suite rooms and first time use)
•
Door open from inside
•
Door closed
•
Deadbolt thrown / released
Thermostat to lock:
•
Room occupied – to enable lock to
enter AutoDND mode
enter AutoDND mode
Motion sensor to thermostat:
•
Motion detected
•
Battery status
Thermostat to motion sensor:
•
Turn off when the room is occupied and
the door is closed
the door is closed
•
Turn on when the door is opened again