Checkpoint Systems Inc. TR7240 ユーザーズマニュアル

ページ / 14
Quick Start Guide: E10 2.0 RF/RFID Pedestals
Page 5 of 9
2.1.2 One Reader for Two Aisles (Dual-Aisle)
 
Figure 5: 
AP configured for 2 Full Aisles (1R2A layout)
1. Use interpedestal coax cable to connect RX3 of AA to RX5 of first PN.
2.  Use interpedestal coax cable to connect RX4 of AA to RX6 of first PN.
3.  Use interpedestal coax cable to connect RX7 of AA to RX5 of second PN.
4.  Use interpedestal coax cable to connect RX8 of AA to RX6 of second PN. 
5.  Use interpedestal network cable to connect “Interpedestal OUT” of first PN to “Interpedestal IN” of AA.
6. Use interpedestal network cable to connect “Interpedestal OUT” of AA to “Interpedestal IN” of second PN.
7.  Connect 12 VDC to the WRTZ reader using power supply system.
2.2 One Reader Two Aisles Extensions
2.2.1 Two Readers Three Aisles (2R3A)
2 full aisles + 2x half aisle
Figure 6: 
2 AP Pedestals configured for “2 Full and 2 half aisles”
In this pedestal layout, the AP pedestals are in positions 1 and 3 (see above). Each system has both front and rear 
RFID Arrays driven by its own internal WRTZ-2000 Reader; meanwhile, in the center aisle position (2) a Passive/
Passive unit is installed, which must have each array connected to the neighboring active. (Half aisles are outside 
the aisle, which makes this configuration suitable when there is a 4-6 meter “MALL Opening” (see Diagrams).
1. Use interpedestal coax cable to connect RX3 of first AA to RX5 of PP.
2.  Use interpedestal coax cable to connect RX4 of first AA to RX6 of PP.
3.  Use interpedestal coax cable to connect RX3 of second AA to RX9 of PP.
4.  Use interpedestal coax cable to connect RX4 of second AA to RX10 of PP.
5.  Use interpedestal network cable to connect “Interpedestal OUT” of first AA to “Interpedestal IN” of PP.
6. Use interpedestal network cable to connect “Interpedestal OUT” of PP to “Interpedestal IN” of second AA.
7.  Connect 12 VDC to the WRTZ reader using power supply system.