Test Procedure
Refer to Calibration Procedure.
SR35/50 Base Station Utility
Initial Setup And Description
Main Display Tool Bar Description
The "Channel Info" button is used to view and setup the frequency information in the SR35/50.
The "Analyze" button reads the internal status of the SR35/50 and displays as such.
The "Update" button is only used when SETUP - DYNAMIC is selected. Pressing "Update" sends the dynamic
settings to the SR35/50 for quick initial testing.  The values are not saved in the SR35/50. It is also used to setup the
default values as used in the channel programming.
The other buttons duplicate "Save", "Open File", "Send Data to Radio" and "Load Data from Radio" as seen on the
Channel Info screen respectively.
Initial Settings
In order to read or send data to the SR35/50 a file must first be created or opened.
Initial Static Settings
Go to SETUP STATIC and set the appropriate values and conditions for the SR35/50. Press "SEND" to send and
store the values inside the SR35/50.  Note that reference, IF frequencies and injection are not stored in the SR35/50,
so this must reflect the actual physical conditions of the SR35/50. The standard reference oscillator is 14.4MHz. The
Standard IF is 90MHz, with high side injection Bands A to I and low side J to X.  The PLL correction factor value is
usually around 120. The fan on temperature is normally set to 40C with the over temperature cutout at 70C.
Channel Programming and Description