S Series Repeater USER MANUAL
©RELM Communications Inc.  Revision 1.0
30
Also see Testing Section
Appendix C
DIP Switch Settings
DIP Switch 1
Channel Selection
There are three methods are available for channel selection (see also the section SR35/50 Base Station Utility).
Software Channel Select via Utility Program:  First ensure that channel 0 is selected on the DIP switch DIP1
located on the Micro Controller Board (all 8 switches in the off position).  Enter the channel number in the Software
Select Channel window on the Channel Info screen and press Select.
Software Channel Select via Serial Command:  First ensure that channel 0 is selected on the DIP switch DIP1
located on the Micro Controller Board (all 8 switches in the off position).  Send the string "chansXXX" where XXX
= a 3 digit number for the channel number.  eg To select channel 5 send the string "chans005".  Baud rate is 9600
BPS.
Hardware Channel Select: Select the fixed channel for the SR35/50 by using the DIP switch DIP1 located on the
Micro Controller Board.  Channel 1 to 255 is available in binary selection.  Switch position 1 is channel 1, position 2
is channel 2, position 3 is channel 4, position 4 is channel 8, position 5 is channel 16, position 6 is channel 32,
position 7 is channel 64, position 8 is channel 128.
A table of DIP switch 1 settings follows, where switch ON is indicated by a "x" in a cell and no entry in a cell
represents a switch OFF.
Channel
SW 1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
0
1
x
2
x
3
x
x
4
x
5
x
x
6
x
x
7
x
x
x
8
x
9
x
x
10
x
x
11
x
x
x
12
x
x
13
x
x
x
14
x
x
x
15
x
x
x
x
16
x
17
x
x
18
x
x
19
x
x
x
20
x
x