Application Notes
LED Interface
The LED signal is used to indicate the working status of the SocketModem.
LED 1 – Heartbeat LED
LED 1 Signal
Heartbeat LED
Blinking
The unit is functioning normally
Off or solid light
The unit is not functioning normally
Ethernet Interface – Non-Isolated Design
Note:
VREF stands for Power in this drawing.
Ethernet Interface – Isolated Design
Isolated Design Application Note
The MT100SEM-L-HV-IP was designed to meet Basic Isolation at 240Vac according to the international medical
directive for safety (EN60601-1). The recommended components for an isolated design comply with the same
standard.
directive for safety (EN60601-1). The recommended components for an isolated design comply with the same
standard.
Recommended Parts
Recommended Capacitors for a Non-Isolated Design:
Manufacturer – NIC Components Corp.
Part Number – NMC0603NPO150J50TRPF
Part Number – NMC0603NPO150J50TRPF