SPECIFICATIONS
Power Measurements
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into your power source when determining
product load.
MTPCIE-H5
Radio
Cellular Call Box
Average Measured Current
TX Pulse (Avg)
Total Inrush Charge
Protocol
Connection No
(Amps) at Maximum Power
Amplitude Current
Measured in
Data (Amps)
(Amps) for GSM850 or
Millicoulomb
Peak Current for HSDPA
3.3 Volts
GSM850
0.056
0.629
2.5
5.27
HSDPA
0.057
0.727
0.804
5.27
Note:
Inrush Current:The input current during power up, or a reset.
MTPCIE-H5-V-BW
Radio
Cellular Call Box
Average Measured Current
TX Pulse (Avg)
Total Inrush Charge
Protocol
Connection No
(Amps) at Maximum Power
Amplitude Current
Measured in
Data (Amps)
(Amps) for GSM850 or
Millicoulomb
Peak Current for HSDPA
3.3 Volts
GSM850
0.062
1.058
2.9
2.51
HSDPA
0.062
0.970
1.052
2.51
Note:
Inrush Current:The input current during power up, or a reset.
MTPCIE-BW
Voltage
Inrush Current
Idle Mode after MT100EOCG
Max Power with Bluetooth and Wi-
(Amps)
Boots Up (Amps)
Fi in Broadcast Mode (Amps)
3.3 Volts
0.056
0.0064
0.326
Note:
Inrush Current:The input current during power up, or a reset.