Andrew Wireless Innovations Group RPT-MR701 ユーザーズマニュアル

ページ / 76
User’s manual for Repeater MR801B Power
M0067A0A.doc
Id.-No 151111
Page 57
02-JUNE-99
Remove the clamping profile at the outside of the housing
by pulling at the mains cable. Open the PG9 threaded joint
with a spanner size 17. Inside the housing remove the
plastic cable clip by unscrewing the tallow-drop screw.
Then use a small screwdriver and open the screws of the
fuse terminal.
Now the mains cable
can be removed by
pulling at the cable. For the installation of a new cable
strip the isolation of a new cable to the length of 18 cm.
Put the screw of the cable gland over the cable then use
the joint rubber and pull it over the cable. This will
guarantee a tight connection. Now insert the cable.
Inside the housing pull an insulated tube with the length
of 8 cm over the wires. Now close the PG9 threaded
joint. Screw the wires to the fuse terminal. Fix the cable
with the plastic cable clip.
Put the cable in the guide shaft and close it with the clamping profile.
9.5 Replacement of the RAM / RTC battery
The RAM / RTC battery of the control module has to be replaced in case of memory loss or
as a preventive measure after approximately three years usage. The RAM / RTC battery is
mounted on the left-hand side of the Repeater underneath the dummy battery backup module
First remove the whole dummy battery backup module ( see figure 9-5 Position of dummy
battery backup module ), which is plugged into the control module. Take off the Lithium
battery by means of a small screwdriver, placed between the battery and the battery socket.
The type of the battery is CR 2450 Lithium 3 V / 500mAh, manufacturer is RENATA.
After replacement of the RAM battery, the control module has its basic settings, date and time
have to be set to the actual value.