battery  power  indication  and 
actual power usage 
Battery life is expired 
Replace it with new battery 
Unclear IR image 
Lens  have  misted  up  or  been 
polluted 
Clean 
lens 
with 
specialized 
equipment 
Unclear visible light image 
Excessively 
dark 
surrounding 
environment 
Take appropriate lighting measures 
There  is  vapor  in  front  of  visible 
light or the visible light is polluted 
Clean  the  front-end  of  visible  light 
with specialized equipment 
Inaccurate 
temperature 
measurement 
Relevant 
temperature 
measurement  parameters  are  set 
incorrectly 
Change parameter  setting  or  restore 
the default parameters directly 
Non-uniformity  correction  has  not 
been implemented for a long time 
Set custom key as compensation key 
in  the  menu,  press  custom  key,  and 
conduct  non-uniformity  correction 
after shutter sounds.   
Temperature  measurement  starts 
immediately after start-up   
To ensure temperature measurement 
accuracy, we recommend you to turn 
on the thermal imager and then wait 
for  5-10  minutes  before  temperature 
measurement. 
No calibration for a long time 
To  ensure  accurate  temperature 
measurement  result,  we  recommend 
you to send back the thermal imager 
for calibration once a year.