Linksys EtherFast® 16-Port 10/100 Auto-Sensing Hub, Desktop EFAH16W-EU ユーザーズマニュアル

製品コード
EFAH16W-EU
ページ / 22
A maximum of Transceivers can be connected together in one segment.
When two hubs are connected via Transceivers together, the same rule of
cascading two 100Mb hubs applies to them. To cascade another hub to
these two hubs (using RJ-45), a switch or repeater must be used.
The Distance Extender is a switched port. This means another 100Mb hub
can be cascaded (with RJ-45) to the hub that has a Distance Extender
Module installed. Two Distance Extender modules can be connected togeth-
er only at Half Duplex. Do NOT set either or both of the Distance
Extender modules to Full Duplex. The Auto-Sensing hubs will not commu-
nicate at Full Duplex.
When using fiber the noise loss has to be calculated. Also, use the same
type of fiber connector (SC or ST) for you fiber cables. If you are using
ST-type connectors and you introduce an SC-type connector module, an SC
to ST converter has to be obtained, or the ST connector may be replaced by
an SC Connector (Note: Changing connectors has to be done professionally
and proper tools have to be used. If you have never worked with fiber
cabling, seek the help of a professional who is familiar with the medium).  
The following table shows the distance limitation when connecting the
Linksys Fiber modules:
Distance (meters/ft)
Cable type
Module in Hub A
Module in hub B
16/50
Multi-Mode
FFOSC1 or FFOSC2,
FFOSC1 or FFOSC2,
62.5/125uM
FFOST1 or FFOST2
FFOST1 or FFOST2
Fiber Optic Cable
SC or ST Type 100BaseFX    SC Type 100BaseFX
Fiber Transceiver Module       Fiber Transceiver 
208/672
Multi-Mode
FFOSC1 or FFOSC2,
FFOSCDE1, FFOSTDE1
62.5/125uM
FFOST1 or FFOST2
SC or ST Type
Fiber Optic Cable
SC or ST Type 100BaseFX    Fiber Distance Extender
Fiber Transceiver Module     
412/1330
Multi-Mode
FFOSCDE1 or FFOSTDE1    FFOSCDE1, FFOSTDE1
(Half Duplex)
62.5/125uM
SC or ST Type
SC or ST Type
Fiber Optic Cable
Fiber Distance Extender        Fiber Distance Extender
14