6 Regulatory & Technical Overview
6.1 UC100 Traffic Awareness Beacon System (TABS)
8
Specification
Characteristics
Compliance
TSO-C199 Class A
FCC ID
2ANAE-UC10X
Applicable Documents
RTCA/DO-181E, RTCA/DO-260B (requirements modified directly in TSO-C199)
Software
RTCA/DO-178C Level C
Hardware
RTCA/DO-254 Level C
Power Requirements
10-38 VDC. Typical 0.5 watt @ 28V (
Altitude
100,000 ft.
Humidity
95% @ 50°C for 6 hours; 85% @ +38°C for 16 hours
Tested to RTCA/DO-160G §6.0 Category A
Operating Temperature
-20°C to +70°C (DO-160G Categories A2, C1)
Transmit Frequency
1090 MHz ± 1 MHz
Transmitter
53 dBm (200W) nominal at RF connector (SMA)
51 dBm (125W) minimum at antenna
Provides for 1.5 dB loss in cable + connectors
Transmitter Modulation
5M65M1D
Receiver Frequency
1030 MHz
Receiver Sensitivity
-74 dBm ± 3 dB (TCAS Replies), -71 dBm ±3 dB (Ground Replies)
8
FAA certifications in progress