6  Regulatory & Technical Overview 
6.1  UC100 Traffic Awareness Beacon System (TABS)
8
 
Specification 
Characteristics 
Compliance 
TSO-C199 Class A 
FCC ID 
2ANAE-UC10X 
Applicable Documents 
RTCA/DO-181E, RTCA/DO-260B (requirements modified directly in TSO-C199) 
Software 
RTCA/DO-178C Level C 
Hardware 
RTCA/DO-254 Level C 
Power Requirements 
10-38 VDC. Typical 0.5 watt @ 28V ( 
Altitude 
100,000 ft. 
Humidity 
95% @ 50°C for 6 hours; 85% @ +38°C for 16 hours 
Tested to RTCA/DO-160G §6.0 Category A 
Operating Temperature 
-20°C to +70°C (DO-160G Categories A2, C1) 
Transmit Frequency 
1090 MHz ± 1 MHz 
Transmitter 
53 dBm (200W) nominal at RF connector (SMA) 
51 dBm (125W) minimum at antenna 
Provides for 1.5 dB loss in cable + connectors 
Transmitter Modulation 
5M65M1D 
Receiver Frequency 
1030 MHz 
Receiver Sensitivity 
-74 dBm ± 3 dB (TCAS Replies), -71 dBm ±3 dB (Ground Replies) 
 
                                                                 
8
 FAA certifications in progress