13 Instructions for Continued Airworthiness
13.1 Scheduled Maintenance
The UC10x series is a transponder device and must be tested and inspected every 24 months subject to the
13.2 Service Life
The instructions for continued airworthiness given in the TC or STC approvals for this product supplements or
supersedes the instructions for continued airworthiness in this manual.
Urban Canyon Flight products are designed and manufactured such that there are no periodic service
requirements necessary to maintain continued airworthiness. Outside of inspections required by regulatory
agencies, no maintenance is required until the equipment does not properly perform its intended function. When
service is required, the unit should be returned to manufacturer for RMA.
13.3 Repairability
The UC10x is not field repairable, and must be returned to the manufacturer.
13.4 Field Firmware Updates
Field updates are not supported. The unit must be returned to the manufacturer.
13.5 ADS-B
The installed ADS-B OUT system must be shown to meet the equipment requirements of 14 CFR 91.227 or
equivalent.
13.5.1 Altimetry Systems and Altitude Reporting Equipment
Altitude reporting equipment connected to the ADS-B system must comply with all applicable 14 CFR 91.217, 14
CFR 91.411, and 14 CFR Part 43 Appendix E test and inspection requirements. Refer to FAA Advisory Circular AC 43-
6C. ADS-B installation (or lack thereof) does not alter these requirements.
13.5.2 Maintenance and Design Changes to Interfacing Components
The ADS-B system interfaces with multiple external components, such as position sources and altimetry sources.
The installer should list all interfacing components in the instructions for continued airworthiness (ICA). It is
important that any future maintenance or design changes to these interfacing components be accomplished in
such a way that continued satisfactory performance of the overall ADS-B system is maintained.
13.5.2.1 Maintenance of the ADS-B System
The ADS-B system installation must include ICA that meet the typical requirements for a system installation, which
includes how to accomplish a complete functional check of the system.
13.5.2.2 ADS-B Source System Components
The installer may not have access to the specific source system ICA to incorporate changes into those specific
documents, the installer must do an analysis of the source systems to determine what maintenance actions on