Texas Instruments HFDEMOKITII ユーザーズマニュアル

ページ / 45
September 2001
      S6350 Reader Reference Guide
9
2.1  General Specification
This chapter describes the electrical and mechanical specifications of the S6350 RI-STU-TRDC-02
reader. Operating at a frequency of 13.56 MHz, this low profile, low power device is designed to be
easily integrated into many systems as an embedded device.  All reader I/O is accomplished through
the use of a 16-pin header connector (labeled as CN1), to include all communication, which is
asynchronous RS232 as controlled by a host system.
2.1.1  Functional Requirements
The following parameters define the functional requirements and operational environment of the
S6350 reader.
 
Parameter
Specifications
Operating temperature
-20
o
C to +70
C
Storage temperature
(500 hours)
-40
o
C to +85
o
C
Thermal shock
-40
o
C to +85
o
C, using MIL-STD-810E, Method 503.3,
for 100 cycles duration, 30 minutes per temperature.
Mechanical shock
5 Gs at 10 ms, half sinusoidal waves, 6 axes (MIL STD-
801E, Method 516.3)
Vibration
15 Hz to 500 Hz, 1 g peak, 30 minutes sweep,
logarithmic (MIL-STD-810E, Method 514.4)
Humidity
500 hours at 80% humidity, non-condensing at 70
o
C
Operating frequencies
13.56 MHz up-link and down-link
Transponder types
13.56 MHz TI Tag-it™ tag (Standard & ISO tag)
Standard compliance
FCC Part 15, Subpart C, “Intentional Radiator”
 
 
2.1.2  Power Supply
Input Voltage
5 ± .5 VDC
Average quiescent current
90mA
Average current during read
200mA (for TAG-IT
 tags)
(Dependent on read rate)
Maximum current during read
250mA
2.1.3  Output Power
Output Power
120mW into 50 Ohms (Typical)
CAUTION:
The S 6350 reader is an intentional radiator, and when
integrated, the integrator is subject to meeting FCC Part
15, Subpart C, and similar tenets under European
Standard EN 300330.