Texas Instruments HFDEMOKITII ユーザーズマニュアル
September 2001
S6350 Reader Reference Guide
9
2.1 General Specification
This chapter describes the electrical and mechanical specifications of the S6350 RI-STU-TRDC-02
reader. Operating at a frequency of 13.56 MHz, this low profile, low power device is designed to be
easily integrated into many systems as an embedded device. All reader I/O is accomplished through
the use of a 16-pin header connector (labeled as CN1), to include all communication, which is
asynchronous RS232 as controlled by a host system.
reader. Operating at a frequency of 13.56 MHz, this low profile, low power device is designed to be
easily integrated into many systems as an embedded device. All reader I/O is accomplished through
the use of a 16-pin header connector (labeled as CN1), to include all communication, which is
asynchronous RS232 as controlled by a host system.
2.1.1 Functional Requirements
The following parameters define the functional requirements and operational environment of the
S6350 reader.
S6350 reader.
Parameter
Specifications
Operating temperature
-20
o
C to +70
o
C
Storage temperature
(500 hours)
(500 hours)
-40
o
C to +85
o
C
Thermal shock
-40
o
C to +85
o
C, using MIL-STD-810E, Method 503.3,
for 100 cycles duration, 30 minutes per temperature.
Mechanical shock
5 Gs at 10 ms, half sinusoidal waves, 6 axes (MIL STD-
801E, Method 516.3)
801E, Method 516.3)
Vibration
15 Hz to 500 Hz, 1 g peak, 30 minutes sweep,
logarithmic (MIL-STD-810E, Method 514.4)
logarithmic (MIL-STD-810E, Method 514.4)
Humidity
500 hours at 80% humidity, non-condensing at 70
o
C
Operating frequencies
13.56 MHz up-link and down-link
Transponder types
13.56 MHz TI Tag-it™ tag (Standard & ISO tag)
Standard compliance
FCC Part 15, Subpart C, “Intentional Radiator”
2.1.2 Power Supply
Input Voltage
5 ± .5 VDC
Average quiescent current
90mA
Average current during read
200mA (for TAG-IT
tags)
(Dependent on read rate)
Maximum current during read
250mA
2.1.3 Output Power
Output Power
120mW into 50 Ohms (Typical)
CAUTION:
The S 6350 reader is an intentional radiator, and when
integrated, the integrator is subject to meeting FCC Part
15, Subpart C, and similar tenets under European
Standard EN 300330.
integrated, the integrator is subject to meeting FCC Part
15, Subpart C, and similar tenets under European
Standard EN 300330.