3.0 Precautions and Preparations
3.1 Precautions
Observe the general safety precautions against personal injury and
equipment damage outlined in the ISM/IM0 at all times.
equipment damage outlined in the ISM/IM0 at all times.
3.2 Preparations
Prior to starting the operations presented in this method, arrange all
materials and tools at the work location so as to minimize fatigue and
inconvenience.
materials and tools at the work location so as to minimize fatigue and
inconvenience.
Inventory the installation components, documentation (installation
manual, floor plans and connectivity chart) and tools you will need.
manual, floor plans and connectivity chart) and tools you will need.
This method contains tasks that require at least two people to carry them
out.
out.
3.3 Sequence
This is a stand-alone method. It is to be performed after Method 02-
0242, Picocell 1900 General Information." See Figure 1 for sequencing
information.
0242, Picocell 1900 General Information." See Figure 1 for sequencing
information.
1.
From the System layout and floor plans, locate where the Hybrids are to
be situated. Mount Back boards to support the hybrids if specified and
Mount the Hybrid(s) to the back-board.
be situated. Mount Back boards to support the hybrids if specified and
Mount the Hybrid(s) to the back-board.
2.
Use the System layout and floor plans to determine where the antennas
are to be located, and mount the antennas. In the case of Omni antennae
it will be required to mount the antenna after the cable has been run and
terminated.
are to be located, and mount the antennas. In the case of Omni antennae
it will be required to mount the antenna after the cable has been run and
terminated.
3.
Run the cable between Hybrids, antennas and Picocell transcievers and
Hybrids as specified on the system layout. Tag and designate all cables.
Hybrids as specified on the system layout. Tag and designate all cables.
4.
Terminate cables with connectors, connect cables to hybrids, antennas
and Picocell 1900 transceivers.
and Picocell 1900 transceivers.
CAUTION
Take precautions when working on ladders to
avoid damage or injury from falling or dropped cables
and objects. RF cable is stiff and unwieldy and the
antennas may be mounted in office or high traffic areas.
Carrying out the installation during off hours to
minimize interference with office staff.
and objects. RF cable is stiff and unwieldy and the
antennas may be mounted in office or high traffic areas.
Carrying out the installation during off hours to
minimize interference with office staff.