Motorola Solutions Inc. 99FT3096 ユーザーズマニュアル

ページ / 153
The general status and condition of the SLR 1000 Repeater can be obtained by observing the three
LED indicators on the front panel. The following tables indicate the LED symbols and their meaning,
and identifies the information conveyed through the LED indicators.
Table 9: SLR 1000 Repeater Front Panel LED Indicators
LED
Definition
Status
Ethernet Link/ Network Connectivity
Reference
Table 10: SLR 1000 Front Panel LED Definitions
LED Function
Name
LED Col-
or
LED State
Status Indication
Power/Status
Off
Off
Off
Green
Solid
Operating normally, with DC power
Red
Flashing
Repeater is disabled (by customer)
NOTICE: The RDAC application is
needed when the Status LED is red
(solid or flashing). This status indi-
cates a minor or major alarm. The
RDAC application is used to identify
the specific alarm and probable diag-
nosis to aid in identifying the FRU at
fault.
Solid
Not operational – major alarm
Amber
Flashing*
Check the Alarm Log – alarm occurred and
cleared but remains latched (configurable)
Solid
Repeater Operational – minor alarm
Ethernet/ Network
Connectivity
Off
Off
No Ethernet connection
Green
Solid
Connectivity/ Linked
Flashing
Attempting to connect to the system
Reference*
Off
Off
For future use
(*) Not supported in this release.
Return to Process
 on page 29
MN003557A01-AF
Chapter 1:  SLR 1000 Repeater
  43