Furuno USA Inc 9ZWRTR113 ユーザーズマニュアル

ページ / 40
3.  MAINTENANCE, TROUBLE SHOOTING
21
3.1
Maintenance
Regular maintenance is important for good performance. Check the points mentioned 
below every 3 to 6 months to keep the antenna unit in good working order. 
Check point
Action
Remedy, remarks
Check points every 3 to 6 months
Cable
Check that all cables are firmly 
connected and are not damaged.
•  Connect a cable if it has loosened.
•  Replace damaged cables.
Exposed 
bolts and nuts
Check that bolts and nuts are not 
corroded and are securely fas-
tened.
•  Replace corroded bolts.
• Tighten loosened bolts. 
•  Coat new bolts with marine sealant.
Radiator
Dust, dirt and salt deposits on 
the radiator cause signal attenu-
ation, resulting in loss of sensitiv-
ity. 
•  Wipe radiator with a freshwater-
moistened cloth.
•  The radiator is made of AES (Acry-
lonitrile-Ethylene-Styrene) resin. 
Therefore, do not used gasoline, 
benzene and the like to clean the ra-
diator.
•  If the radiator is iced, use a wooden 
or plastic headed hammer to re-
move the ice. DO NOT use a steel 
hammer.
Ground con-
nection
Check for tight connection and 
rust.
•  Fasten if loosened.
•  Remove rust if present.
Check points every year
Check the scanner unit for rust, 
corrosion and chipped paint.
•  If the scanner unit has rusted or the 
paint has chipped, paint the affected 
area.
•  Paint only the scanner unit. Do not 
paint the antenna (see figure be-
low). Paint on the antenna can 
cause loss of sensitivity and crack 
the antenna.
: Do NOT paint.
: Painting area