63
11
OTHER FUNCTIONS
New2001
D
Cooling fan control
Selects the cooling fan control condition from Auto and ON.
• Auto (AT) : The fan rotates during transmit and for 2 min.
after transmission.
• ON (ON) : The fan continuously rotates. 
D
Data transmission speed
Selects the data transmission speed for packet operation
from 1200 bps and 9600 bps.
D
Squelch delay
Selects squelch delay from short and long to prevent re-
peated opening and closing of the squelch during reception
of the same signal.
• S
: Short squelch delay.
• L
: Long squelch delay
D
Microphone sensitivity
Selects the microphone sensitivity from high (H) and low (L)
to suits your preference.
D
Squelch attenuator
Turns the squelch attenuator function ON and OFF.
• ON
: The squelch attenuator activates when [SQL]
control is set between 12 o’clock and fully
clockwise position.
• OF
: The squelch attenuator does not function.
IC-208H.qxd  03.2.26 20:00  Page 63 (1,1)