ADVAnCED PARAMETERS
12. First channel - time parameter for delay/auto ON/OFF modes
This parameter allows to set time parameter used in timed modes. 
Available settings: 0  (0.1s), 1-32000 (1-32000s, 1s step) - time  
parameter
Default setting: 
50 (50s)
Parameter size:
2 [bytes]
13. First channel - pulse time for flashing mode
This parameter allows to set time of switching to opposite state in 
flashing mode.
Available settings: 1-32000 (0.1-3200.0s, 0.1s step) - time param-
eter
Default setting: 
5 (0.5s)
Parameter size:
2 [bytes]
15. Second channel - operating mode (FGS-223 only)
This parameter allows to choose operating for the 1st channel con-
trolled by the S2 switch. 
Available settings: 0 - standard operation
1 - delay On
2 - delay OFF
3 - auto On
4 - auto OFF
5 - flashing mode
Default setting: 
0
Parameter size:
1 [byte]
16. Second channel - reaction to switch for delay/auto ON/OFF 
modes (FGS-223 only)
This parameter determines how the device in timed mode reacts to 
pushing the switch connected to the S2 terminal.
Available settings: 0 - cancel mode and set target state
1 - no reaction to switch - mode runs until it ends
2 - reset timer - start counting from  the beginning
Default setting: 
0
Parameter size:
1 [byte]
17. Second channel - time parameter for delay/auto ON/OFF 
modes (FGS-223 only)
This parameter allows to set time parameter used in timed modes. 
Available settings: 0  (0.1s), 1-32000 (1-32000s, 1s step) - time  
parameter
Default setting: 
50 (50s)
Parameter size:
2 [bytes]