Door/Window Contact
  
(V-DW11-345)
 
Quick Reference  
 
Programming Instructions  
(For more details, go to the Support page at: 
Vivint.com
, and the KIM site at: 
corp.vivint.com/sites/KIM/
  Loop 1: Use when the external input is used. 
  Loop 2 (default): Use when the magnet is used directly with the sensor. 
Installer Test  
Once installed, open and/or close the door or window for which the DW11 is installed so that the sensor will 
transmit to the Vivint Control Panel while the panel is in installer test mode. 
 
 
 
User Test  
Open and/or close the door or window for which the DW11 is installed to ensure the sensor is transmitting 
correctly to the panel. The panel should recognize the state change of the object that is being monitored. 
Specifications  
Wireless Signal Range 
350 feet (106.7 m), open air 
Battery 
Panasonic CR2032 or equivalent lithium battery 
Transmitter Frequency 
345 MHz 
Code Outputs 
Open, Close, Tamper, Low Battery, Loss of Supervision 
Supervisory Interval 
70 minutes per signal (12 hours for panel to report supervision failure) 
Operating Temperature Limits 
32° to 120°F (0° to 49°C) 
Relative Humidity 
5-95% Non-Condensing 
 
PRINT INSTRUCTIONS: REFERENCE SHEET V-DW11-345 P/N 77-000002-001 REV 1.1  |   
INK: BLACK  |  MATERIAL: 20 LB MEAD BOND  |  SIZE: 5.50" X 8.50" SCALE 1:1  |   
FOLDS: TRI-FOLD VERTICAL, TRI-FOLD HORIZONTAL (TO FIT IN BOX) 
 
For external switch usage: 
1.
 Secure the external contact switch in the desired location. 
2.
 If necessary, drill a hole to allow the external contact wires to reach 
the desired location of the sensor. 
3.
 Feed the wires through the drilled hole and then through the access 
hole in the back of the sensor. 
4.
 Connect the wires into the NC dry contact connector. 
NOTE: With solid-core wire you should be able to push the wire 
directly into the connector. Press the small button on the connector to 
release the wire. 
5.
 Mount the sensor in the desired location and reattach the sensor cover 
(store excess wire in the device). 
 
Installation Instructions   
For internal switch usage: 
1.
 Secure the sensor to the door or window frame, or other object, using 
the supplied adhesive or screws. 
NOTE: It is recommended to install the sensor on the side that  
will be moving less (e.g. the doorframe instead of the door). 
2.
 Secure the included magnet adjacent to the sensor on the door,  
window, or other object using the supplied adhesive or screws. 
NOTE: If necessary, use the supplied magnet spacer to better align the 
magnet and sensor. Remove the back from the magnet using a small 
flathead screwdriver and replace it with the spacer back. 
 
The Vivint Door/Window Contact (DW11) is a sensor device that can be installed 
on doors, windows, and other objects in order to monitor open and closed states. 
The DW11 transmits a signal to the panel when the magnet is moved away from, 
or close to, the DW11 sensor. 
The DW11 device has an external input for NC (Normally Closed) dry contact 
devices, or it can be used with the supplied magnet directly with the sensor.  
The DW11 is also equipped with a cover tamper for additional security.