Installation instructions for the following models:  
EDGE│home™ Outlet Control, Battery Switch, Powered Switch, Lighting Control, 
Dry Contacts, Wall Control, Dual Lighting Control, Single Monitoring Device, and 
Dual Monitoring Device. 
 
WARNINGS AND CAUTIONS:
  
•  DISCONNECT POWER AT CIRCUIT BREAKER OR FUSE WHEN SERVICING, 
INSTALLING OR REMOVING FIXTURE. 
•  TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE 
ELECTRICAL CODES AND REGULATIONS. 
•  IF YOU ARE UNSURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A 
QUALIFIED ELECTRICIAN. 
•  USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY.  
•  TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER 
EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE, MOTOR 
OPERATED APPLIANCE, FLUORESCENT LIGHTING FIXTURE, OR TRANSFORMER 
SUPPLIED APPLIANCE.  
•  EDGE│home™ DEVICES ARE NOT FOR USE WITH MEDICAL OR LIFE SUPPORT 
EQUIPMENT 
Exercise extreme caution when using EDGE│home™ devices to control 
appliances.  Because the controlled appliance(s) could be in a different room than 
the EDGE│home™ device, these appliances could be inadvertently turned on 
when not intended due to an incorrect button press, etc.  For that reason, we 
recommend the following action:  
 
EDGE│home™ INTRODUCTION  
Thank you for your purchase of a EDGE│home™ product.  The EDGE│home™ 
devices allow for intelligent energy monitoring and control of lighting and 
electrical appliances. The devices incorporate proprietary GEP™ protocol that 
allows wireless two-way communication and gives the ability to remotely control 
these devices by a GEP™-compatible controller.  Controlled devices are easily 
paired with switches through the user interface on the tablet to allow direct 
control from the switches. 
EDGE│home™ devices controlling  appliances which present a hazardous 
condition due to unattended or unintentional or automatic power-on control 
such as electric heating devices should be removed from pairings to remote 
switches and should not be used in scenes. 
Double check all pairings before completing the installation. 
Other than the battery on the EDGE│home™ ™ BATTERY SWITCH, there are no 
serviceable parts in the EDGE│home™ ™ devices  
 
SPECIFICATIONS:
 
Input Voltage: 120VAC / 60Hz 
Input Current: 2mA standby, 25mA maximum 
Signal Frequency: 907.245MHz - 927.173MHz 
 
BATTERY SWITCH
  
Input Voltage: 3V DC, or 6V - 9V DC 
Input Current: 30mA maximum 
 
ELECTRICAL LOAD RATINGS: 
 
OUTLET CONTROL  
15A, 120VAC (1800W) Resistive 
600W (Incandescent) 
½ HP (motor) 
POWERED SWITCH, (DUAL) LIGHTING CONTROL, WALL CONTROL  
Load ratings ON/OFF: 
15A, 120VAC (1800W) Resistive 
600W (Incandescent) 
½ HP (motor) 
Load Rating for DIMMING: 
150W (Dimmable CFL/Dimmable LED/Incandescent) 
DRY CONTACTS  
15A , 120VAC (1800W) Resistive 
600W (Incandescent) 
½ HP (motor) 
10A, 35VDC (resistive) 
 
INSTALLATION INSTRUCTIONS  
It is recommended that a qualified electrician perform the installation of the 
EDGE│home™ devices. Recommended minimum wall box depth is 3”.  
For indoor use only.  
For a list of approved bulbs to be used with EDGE│home™ (Dual) Lighting 
Control and EDGE│home™ Wall Control, please visit mygreenedge.com
  
Refer to the wiring diagrams in Figures 1-5  for the connections to the 
appropriate device.  Note that the Switch in Figure 4 is battery powered and does 
not have connections to line power.  The Dry Contacts in Figure 6 connect a 
common (SW_COM/DRY IN) to two (2) separate N.O. Dry Contacts.  
  
1.  Make sure all power to the branch circuit has been disconnected by turning 
off the circuit breaker or disconnecting the fuse at the electrical panel. 
2.  If applicable, remove the faceplate from the existing wall outlet/switch, 
remove the outlet/switch from the wall box and disconnect the wires from 
the existing outlet/switch.  
3.  Identify the wires on the EDGE│home™ device that match the appropriate 
wiring diagrams in Figures 1-8.  The wires should be labeled on the plastic 
case of the EDGE│home™ device.  
4.  Using wire strippers, remove 5/8” of insulation from each of the wires 
connected to the EDGE│home™ device. 
5.  Install the EDGE│home™ device by connecting the wires as per the wiring 
configuration in Figures 1-8 for the appropriate device.  The EDGE│home™ 
device does not require a ground wire, but the switch or outlet should be 
grounded to the green or bare wire from the circuit. 
 
 
6.  After all connections have been made, ensure that all wire connections are 
firmly attached and there is no exposed copper. 
7.  Place the EDGE│home™ device and the connected wires into the wall box 
along with the connected outlet/switch.  Use caution not to crush or pinch 
wires.  Secure the assembly to the junction box.  
8.  Before installing the faceplate, restore power to the circuit and test the 
functionality. 
9.  Install faceplate. 
   
Important Note: 
Changes  or  modification  not  expressly  approved  by  Green  Edge  Technologies,  Inc. 
(Green  Edge)  could  void  the  user’s  authority  to  operate  the  device.  The  Federal 
Communication  Commission  Radio  Interference  Statement  includes  the  following 
paragraph: This equipment has been tested and found to comply with the limits for a 
class B Digital Device, pursuant to part 15 of the FCC Rules.  These limits are designed 
to  provide  reasonable  protection  against  harmful  interference  in  a  residential 
installation.  This device uses, generates and can radiate radio frequency energy, and 
if  not  installed  and  used  in  accordance  with  the  instruction,  may  cause  harmful 
interference  to  radio  communication.  However,  there  is  no  guarantee  that 
interference will not occur  in a particular installation.  If this equipment does cause 
harmful  interference  with  respect  to  radio  or  television  reception,  which  can  be 
determined by turning the equipment off and on, the user is encouraged to try and 
correct the interference by the following measures: 1) separate the devices from this 
equipment 2) reorient the device with respect to this equipment 3) consult the dealer 
or an experienced radio technician for help 
Operation is subject to the following two conditions: 
1)  This device may not cause interference 
2)  This device must accept any interference, including interference that may 
cause undesired operation of the device 
 
LIMITED WARRANTY 
Green Edge’s standard One Year Limited Product Warranty (including warranty 
exclusions) is incorporated by reference herein, unless agreed to otherwise by Green 
Edge in writing.   Please carefully review and refer to the full Warranty on line at 
www.edgehome.com/legal/warranty, or consult your local sales representative for 
specific warranty details. Green Edge warrants this device, excluding battery, to be 
free from defects in the workmanship or materials, under normal use and service, for 
a period of one (1) year from the date of purchase by the consumer. If at any time 
during the warranty period the product is determined to be defective or 
malfunctions, Green Edge shall repair, replace or refund it at Green Edge’s 
option. Green Edge's Warranty does not apply to products that are not EDGE│home™ 
-branded, even if packaged or sold with EDGE│home™ devices. Non- EDGE│home™ 
branded products may have the benefit of a manufacturer's warranty provided by the 
product manufacturer. Green Edge’s Warranty is buyer's sole remedy and is in lieu of 
all warranties, expressed or implied, including those of merchantability and fitness for 
a particular purpose. In no event shall Green Edge be liable for consequential, special, 
or indirect damages of any party.  
 
 
 
INSTALLATION MANUAL