2, Specification
Equipment compatibility
Heat pump system:
3 heating stages: Y1, Y2 and W1 (auxiliary heating)
2 cooling stages: Y1 and Y2
Emergency heating: W1
Reverse valve type O or B selectable
Emergency heating HE/HG type selectable
Heat pump fault feedback (L) indication
2 cooling stages: Y1 and Y2
Emergency heating: W1
Reverse valve type O or B selectable
Emergency heating HE/HG type selectable
Heat pump fault feedback (L) indication
Non heat pump system:
2 heating stages: W1 and W2
2 cooling stages: Y1 and Y2
HE/HG selectable
Jumper for separated heating and cooling circuit
2 cooling stages: Y1 and Y2
HE/HG selectable
Jumper for separated heating and cooling circuit
Terminals
Number of terminals:
9 + 1 (reserved for future)
Terminals for heat pump
Y1, Y2, W1, G, O/B, L, Rc, C
Terminals for non heat pump
Y1, Y2, W1, W2, G, Rc, Rh, C
User interface
Display:
Segmented type LCD with blue backlight
Input:
Capacitive type “Touch Dial”
Button:
Hidden reset key
Clock and Calendar
Clock synchronization:
via Internet.
Clock free run accuracy:
+/-2 seconds per day .
Time display format:
AM/PM / 24 hours format user selectable.
DST:
Enable / Disable user selectable. Clock automatically adjusted if DST is enabled.
Time zone:
-2 to +3 hours user selectable.
Calendar:
Valid through 2000 to 2099
Calendar display format:
MM-DD-YY. (Calendar is not displayed on home screen)
Temperature Measurement
Temperature display format:
Fahrenheit or Celsius user selectable.
Temperature display range:
Fahrenheit: 32°F ~ 99°F, 1°F display resolution
Celsius: 0°C ~ 40°C, 1°C display resolution
Celsius: 0°C ~ 40°C, 1°C display resolution
Temperature measurement accuracy: +/-0.5°C (15°C to 25°C room temperature)
+/-1.0°C (full temperature measurement range)
Calibration:
Yes, via software, user adjustable.
+/-7°F in 1°F resolution.
+/-4°C in 0.5°C resolution.
+/-7°F in 1°F resolution.