JADAK a business unit of Novanta Corporation SM-MN-SH ユーザーズマニュアル
30
13
Customizing System Parameters
System parameters let you configure reader settings to customize the reader for your environment. All
parameters can be changed in both volatile and non-volatile memory. When changing a parameter in volatile
memory the change in the parameter is realized immediately, but is reset upon power-cycling the M1-Mini.
Alternatively, when changing a parameter in non-volatile memory the change in the parameter is not
realized immediately, but will only be realized after power-cycling the M1-Mini.
The following table summarizes the parameters for the M1-Mini.
Name
Parameter
Address
Request
Blocks
Length
(bytes)
Parameter Values
Factory Default
Parameter Value
Specifies
READ
WRITE
SERIAL
NUMBER
0x00
2
4
0x00000000-
0xFFFFFFFF
custom
serial number
custom
no
FIRMWARE
VERSION
0x01
1
2
0x0000-0xFFFF
depends on
release
firmware version
yes
no
READER ID
(RID)
0x02
1
1
0x00-0xFF
0xFF (“no RID”)
reader network ID
yes
yes
BAUD RATE
0x03
1
1
0xFF
0x00
0x01
0x02
0x03
0x04-0xFE
0x00
4800
9600
19200
38400
57600
reserved
no
yes
SLEEP
MODE
0x04
1
1
0x00
0x01-0xFF
not applicable
sleep active
no
yes
Reserved
0x05
None
no
no
Reserved
0x06
None
no
no
USER PORT
DIRECTION
0x07
1
1
0x00
defines pins as inputs
or outputs
yes
yes
USER PORT
VALUE
0x08
1
1
0x00
writes values of
output pins reads
values of input pins
yes
yes
Reserved
0x09–0x11
None
no
no
STARTUP
COMMAND
0x12
1
1
see detailed
description
0x00
see notes
no
yes
Reserved
0x13–0x80
None
no
no
Table 13-1: M1-Mini System Parameters