Veridt Reader Terminal Installation Guide  
Reader Communications Options 
 
All Veridt reader platforms are based on a common architecture and therefore installation instructions apply to all read-
ers.  This common architecture allows for multiple communications interface options as well as options for interfacing to 
third party software for High Assurance security solutions and Mode Control (setting the operational mode in multi-
format readers; e.g., card + PIN, card + Bio, etc.).  The reader is equipped with two communications interfaces:  1) 
Wiegand which can be configured up to 512 bits and 2) Serial RS-485 which can also be converted to Ethernet.  The 
Wiegand  output is typically pre-configured for the chosen application, but is also field configurable using the MultiMode 
SDK.  Serial/Ethernet  communications are typically preconfigured for the  chosen application. 
 
The feature set and application determines the combination of hardware and software required. 
 
 
 
Reader Communi-
cations Interface 
Hardware 
Interface 
Access Control 
Panel 
Communica-
tions Interface 
 
Hardware  
Interface 
 
Software 
Wiegand 
 
None 
 
 
 
Wiegand
 
RS-485 
  
Half duplex 
 None 
  
 
RS-485 
Half duplex 
Veridt EWACs 
 
pivCLASS PACS 
Service Admin 
RS-485 
Half duplex 
Veridt EWACs 
 
Veridt Mode  
Control  
RS-485 
Full duplex 
HID PAM 
 
pivCLASS PACS 
Service Admin 
Veridt EWAC  
Communications Interface 
HID 
PAM