Maiden Rock Communications LLC MRC565-47-50 ユーザーズマニュアル

ページ / 209
OPERATIONS 
Page 90 
MRC-565 Packet Data Radio Operations & Maintenance 
 
When a CR1000 is connected to other CS-I/O-enabled devices, it will be necessary to use an 
interface adapter available from CSI, such as the SC105. This device manages the RI/ME lines 
internally, so this option must be turned off in the radio using the command: 
 
CR1000, MODEM ENABLE, OFF. 
 
5.8.13  Reading CR1000 Internal Pointers and Error Statistics 
 
The CR1000,STAT command will read and display the CR1000 internal pointers and error 
counters. The following example shows the response format: 
 
+cr1000,stat 09/22/05 09:06:20 
 
     /--------First--------\ /--------Current------\ /--------Last---------\ 
 Grp   Date    Time   Record   Date    Time   Record   Date    Time   Record 
 === ======== ===== ======== ======== ===== ======== ======== ===== ======== 
  01 08/19/05 09:19 00000000 09/22/05 09:06 00047490 09/22/05 09:06 00047489 
+
 
 
5.8.14  Displaying Status Table Data 
 
Data in the Status Table can be displayed, but cannot be “set”.  To display a single value in the 
Status Table, use the command: CR1000, STATUS, field-name. 
Example:  
 
+CR1000,STATUS,OSVERSION 02/23/14 12:27:11 CR1000.Std.26.2013.08.27.02 
 
To display a list of all status values, use the command CR1000, STATUS, ALL. 
Example: 
 
+cr1000,status,all  02/23/14 11:09:56  Waiting... 
  OSVersion                  CR1000.Std.26.2013.08.27.02 
  OSDate                     130827 
  OSSignature                56366 
  SerialNumber               51256 
  RevBoard                   019.008 
  StationName                51256 
  PakBusAddress              1 
  ProgName                   CPU:CR1000.CR1 
  StartTime                  2D68A731:01312D00 
  RunSignature               50227 
  ProgSignature              9141 
  Battery                    12.03465 
  PanelTemp                  26.46690 
  WatchdogErrors             0 
  LithiumBattery             3.45162 
  Low12VCount                0 
  Low5VCount                 0 
  CompileResults             CPU:CR1000.CR1 -- Compiled in SequentialMode. 
 
  StartUpCode                0