Maiden Rock Communications LLC MRC565-47-50 ユーザーズマニュアル
OPERATIONS
Page 90
MRC-565 Packet Data Radio Operations & Maintenance
When a CR1000 is connected to other CS-I/O-enabled devices, it will be necessary to use an
interface adapter available from CSI, such as the SC105. This device manages the RI/ME lines
internally, so this option must be turned off in the radio using the command:
CR1000, MODEM ENABLE, OFF.
5.8.13 Reading CR1000 Internal Pointers and Error Statistics
The CR1000,STAT command will read and display the CR1000 internal pointers and error
counters. The following example shows the response format:
+cr1000,stat 09/22/05 09:06:20
/--------First--------\ /--------Current------\ /--------Last---------\
Grp Date Time Record Date Time Record Date Time Record
=== ======== ===== ======== ======== ===== ======== ======== ===== ========
01 08/19/05 09:19 00000000 09/22/05 09:06 00047490 09/22/05 09:06 00047489
+
/--------First--------\ /--------Current------\ /--------Last---------\
Grp Date Time Record Date Time Record Date Time Record
=== ======== ===== ======== ======== ===== ======== ======== ===== ========
01 08/19/05 09:19 00000000 09/22/05 09:06 00047490 09/22/05 09:06 00047489
+
5.8.14 Displaying Status Table Data
Data in the Status Table can be displayed, but cannot be “set”. To display a single value in the
Status Table, use the command: CR1000, STATUS, field-name.
Example:
+CR1000,STATUS,OSVERSION 02/23/14 12:27:11 CR1000.Std.26.2013.08.27.02
To display a list of all status values, use the command CR1000, STATUS, ALL.
Example:
+cr1000,status,all 02/23/14 11:09:56 Waiting...
OSVersion CR1000.Std.26.2013.08.27.02
OSDate 130827
OSSignature 56366
SerialNumber 51256
RevBoard 019.008
StationName 51256
PakBusAddress 1
ProgName CPU:CR1000.CR1
StartTime 2D68A731:01312D00
RunSignature 50227
ProgSignature 9141
Battery 12.03465
PanelTemp 26.46690
WatchdogErrors 0
LithiumBattery 3.45162
Low12VCount 0
Low5VCount 0
CompileResults CPU:CR1000.CR1 -- Compiled in SequentialMode.
StartUpCode 0