BEA 10TD9001HH4 ユーザーズマニュアル

ページ / 4
Page 2 of 4  
75.5858.02 900 MHZ INDUSTRIAL 20160205
• 
The device should not be used for purposes other than its intended use. All other uses cannot be guaranteed by 
the manufacturer of this device.  
• 
The installer of the door system is responsible for carrying out a risk assessment and installing this device and the 
door system in compliance with applicable national and international regulations and standards on door safety. 
• 
The manufacturer of this device cannot be held responsible for incorrect installations or inappropriate adjustments 
of this device.
PRECAUTIONS
 
q
Shut off all power going to header before attempting any wiring procedures.
 
q
Maintain a clean & safe environment when working in public areas.
 
q
Constantly be aware of pedestrian traffic around the door area.
 
q
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions 
by the door.
 
q
ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling 
any board ensure you dissipate your body’s ESD charge.
 
q
Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires 
and cause damage to equipment.
 
q
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
 
q
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be 
performed by BEA, Inc. Unauthorized disassembly or repair: 
1.  May jeopardize personal safety and may expose one to the risk of electrical shock. 
2.  May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
Hand Held Configuration
INSTALLATION
Wiring
TERMINAL:
1
2
3
4
5
LABEL:
12-24 V
12-24 V
COM
NO
NC
WIRE COLOR:
red
black
white
green
yellow
SIGNAL:
+ voltage - voltage
common
normally-open
normallyclosed
DESCRIPTION:
power
relay contacts
SETUP
DIP Switches
DIP
STATUS FUNCTION
DESCRIPTION
1
PUL
Pulse Relay
pressing transmitter activates and holds relay according to DIP 2 and 3
TOG
Toggle 
Relay
pressing transmitter once activates and holds relay indefinitely
pressing transmitter again deactivates relay immediately (no hold)
2
(PUL only)
0.5s
0.5 second 
hold time
relay remains active for 0.5 seconds after transmitter is...
pressed [STD]               released [EH]
10s
10 second 
hold time
relay remains active for 10 seconds after transmitter is...
pressed [STD]               released [EH]
3
STD
standard 
hold
relay acts according to DIP 1 and 2
(does not matter if transmitter is pressed/released or pressed/held)
EH
extended 
hold
relay remains active as long as transmitter is pressed and held
once released, relay acts according to DIP 1 and 2
1 2 3
ON
1
2
3
Set DIP switches as desired.
Press transmitter twice (blue LED 
on receiver will illuminate).
Press and release desired learn button 
(red LED on receiver will illuminate)
1
.
NOTES:  
1
If Learn w/ Delay button is used, adjust potentiometer (1 s to 30 s).