heat  and  combustion 
products 
rise 
to 
the 
ceiling 
and 
spread 
horizontally.     
Mounting  the  alarm  on 
the ceiling in the center 
of  the  room  places  it 
closest  to  all  points 
in  the  room.    When 
mounting a detector on 
the  ceiling,  locate  it  at 
a minimum of 4 inches 
(10  cm)  from  the  side 
wall  (see  Figure  3).    If 
installing the detector on the wall, use an inside wall with 
the top edge of the device at a minimum of 4 inches (10 cm) 
and a maximum of 12 inches (30.5 cm) below the ceiling 
(see Figure 4).
SLOPED  CEILING  INSTALLATION:  According  to  the 
National Fire Protection Association (NFPA) Fire Code 72, 
one should install smoke detectors on sloped, peaked or 
cathedral ceilings at or within 3 feet (0.9 m) of the highest 
point (measured horizontally).  Do not install the Smoke/
CO  detector  in  the  peaks  of  vaulted  ceilings,  “A”  frame 
ceilings, or gabled roofs (see Figure 4).  Smoke detectors 
in rooms with ceiling slopes greater than 1 to 8 feet (0.3 to 
2.4 m) horizontally should be located on the high side of the 
room.  A row of detectors should 
be  spaced  and  located  with  3 
feet (0.9m) of the peak of the 
ceiling  measured  horizontally. 
REMOVING  THE  BRACKET:  
Remove  the  bracket  from 
the  back  of  the  Smoke/CO 
detector  by  holding  the  rim 
of  the  bracket  and  twisting  it 
counter-clockwise  (to  the  left) 
as shown here.  Once removed, 
proceed to install the batteries.   
The Smoke/CO detector 
requires  three  (3)  AA 
Energizer  L91  lithium 
batteries.    Open  the 
battery covers and insert 
a battery into each of the 
three 
compartments.  
The  battery  polarity 
markings  on  the  cover 
and  inside  of  each 
battery 
compartment 
must be adhered to.  The 
battery  compartments 
are  fitted  with  a  red 
latch  that  will  prevent 
the detector from locking 
onto the bracket if there are no batteries inside.  All three 
batteries must be properly installed  and in good condition 
for the unit to operate.  Removal of any of the batteries 
will render the detector inoperative.  Replacement batteries 
may  be  purchased  at  your  local  retailer.    Only  use  the 
batteries specified.
MOUNTING  THE  BRACKET:      The  detector  must  be 
mounted  on  a  wall  or  ceiling  with  its  bracket.    It  is  not 
designed for use as a tabletop device. Hold the bracket
against the selected installation location (wall or ceiling) 
and mark the center of the holes with a pencil.  Drill a hole 
through each pencil mark and fasten the bracket to mounting  
surface  with  two  (2)  screws.    Once  mounted,  carefully 
align the detector with the bracket and rotate it clockwise 
(to the right) until the device is locked in place.  Gently pull 
the detector outward to verify that it is securely attached.   
TESTING:  Test both sensors with the Monitoring Center 
once installation is complete.  Press and hold down each 
test button (separately) until the built-in siren sounds and 
the  HELP  PERS  base  unit  begins  to  enunciate  that  an 
alarm has been activated.  Wait for a Life Alert Operator 
to respond and confirm a successful test.  Make sure to 
conduct  a  separate  test  for  each  sensor.    The  Smoke/
CO  detector  must  be  tested  regularly  to  ensure  that 
the  batteries  and  alarm  circuits  are  in  good  operating 
condition.  The test buttons for the Smoke and CO sensors 
may also be used to enroll sensors.
WARNING: The tests buttons are the only way 
to  properly  test  the  smoke  and  CO  sensors. 
Never use smoke or vehicle exhaust as they may cause 
permanent damage and void your warranty. 
To keep your Smoke/CO detector in good working order, 
please follow these simple steps.  Verify alarm siren, LED 
lights, and battery operation by pushing the test buttons at 
least once a week.  Remove the device from the mounting 
bracket and vacuum the detector cover and vents with a 
soft brush attachment once a month to remove dust and 
dirt.    Reinstall  immediately  after  cleaning  and  then  test 
using the tests button.  Never attempt to disassemble the 
unit  or  clean  inside  of  it  as  this  will  void  your  warranty.  
Never use detergents or solvents to clean the unit.  When 
household cleaning supplies or similar contaminates are 
used,  the  area  must  be  well  ventilated.    The  following 
substances can damage the sensors and may cause false 
readings: methane, propane, isobutene, isopropanol, ethyl 
acetate, hydrogen sulfide, sulfide dioxides, alcohol base 
products, paints, thinner, solvents, adhesives, hair spray, 
after shave, perfume, and some cleaning agents.  Do not 
paint  the  device.    Paint  will  seal  the  vents  and  interfere 
with its ability to detect smoke and CO.  Move the detector 
prior  to  performing  any  of  the  following:  staining  or 
stripping wood floors or furniture, painting, wall papering, 
using adhesives.  Store the detector in a plastic bag during 
any of the above projects to help protect the sensors from
HELP PERS  
SUPERVISED
WIRELESS COMBINATION
SMOKE/CO DETECTOR
INSTALLATION 
INSTRUCTIONS
MODEL NO. LASD-01
®
This  installation  instruction  guide  will  introduce  you  to  the 
basic features, operations, and safety considerations of the 
Life Alert HELP PERS combination Smoke/Carbon Monoxide 
(CO)  detector.    Please  take  the  time  to  thoroughly  read 
this guide and save it for future reference.  The detector is 
designed  to  automatically  and  independently  sense  both 
smoke  (not  flame)  and  CO  gas  in  an  ordinary  residential 
environment.    It  provides  an  early  warning  of  developing 
smoke  and  CO  events  by  sounding  a  built-in  85  decibel 
alarm siren and transmitting an alarm signal to the Life Alert 
Monitoring Center via the HELP PERS base unit.  
CAUTION!!  This  device  will  only  indicate  the  presence 
of smoke and CO gas at the sensor.  Smoke and CO gas 
may  be  present  in  other  areas  of  the  residence.  
Effective  pre-warning  of  smoke  and  CO  events  is 
only  possible  if  the  detector  is  located,  installed 
and maintained as described here in this guide.  If you have 
any questions about this device, please contact the Life Alert 
Technical  Service  Department  at  1-800-451-7858.    16027 
Ventura Blvd. Suite 400 Encino CA 91436, U.S.A
The  Smoke/CO  detector  will  operate  and  alert  you  to  the 
following conditions in the manner described here: 
FEATURES
SMOKE  ALARM:
    Utilizing  photoelectric  technology,  the 
smoke sensor monitors the air for products of combustion
that are produced when something is burning or smoldering.  
When smoke particles in the smoke sensor reach a specified 
concentration, the alarm siren will sound.  The alarm pattern 
is three (3) short alarm sirens with three (3) corresponding 
flashes  of  the  red  LED  light.    This  pattern  will  repeat  until 
the  smoke  event  is  eliminated.   The  smoke  alarm  will  take 
precedence  when  both  smoke  and  CO  are  present.    For 
increased  protection,  Life  Alert  recommends  that  both 
ionization  and  photoelectric  detectors  be  installed  in  the 
residence.
CO ALARM:    Utilizing  electrochemical  technology,  the  CO 
sensor monitors the air for the presence of carbon monoxide.  
When there are high levels of CO present, or low levels of 
CO present over a longer period of time, the alarm siren will 
sound.  The alarm pattern is four (4) long alarm sirens with 
four  (4)  corresponding  flashes  of  the  red  LED  light.    This 
pattern will repeat until the CO event is eliminated.  The CO 
sensor is designed to detect carbon monoxide gas from ANY 
source  of  combustion.   
IT IS NOT DESIGNED TO DETECT 
ANY OTHER GAS.
TEST BUTTONS: 
  To conduct a local test, push the two test 
buttons  at  the  same  time  to  verify  proper  Smoke  and  CO 
sensors operation. If both test buttons are pressed, the alarm 
pattern is one (1) short alarm siren with one (1) corresponding 
steady flash of the red LED light. 
LOW  BATTERY:     The  device  is  powered  by  three  (3) AA 
Energizer  L91  lithium  batteries.  When  the  batteries  are  low 
and need to be replaced, the device will chirp once and the 
amber  LED  light  will  flash  once  every  fifty  (50)  seconds. 
The pattern will repeat until the batteries are removed (and 
replaced) or the batteries cease functioning.
SMOKE TROUBLE:  When there is a trouble issue with the 
Smoke sensor, the device will chirp three (3) times and the 
amber LED light will flash once every fifty (50) seconds.
SMOKE LOW SENSITIVITY:  When there is a low sensitivity 
issue  with  the  Smoke  sensor,  the  device  will  chirp  two  (2) 
times and the amber LED light will flash once every fifty (50) 
seconds.
CO  TROUBLE:    When  there  is  a  trouble  issue  with  the 
CO  sensor,  the  device  will  chirp  once  and  the  amber 
LED  light  will  flash  two  (2)  times  every  fifty  (50)  seconds. 
 
END OF PRODUCT LIFE:   After five (5) years of cumulative 
use, the device will chirp once and the amber LED light will 
flash  four  (4)  times  every  fifty  (50)  seconds.  This  indicates 
that the device must be replaced immediately as it may not 
be able to detect CO in this condition. Please call the Life Alert 
Technical Service Department at 1-800-451-7858 for further 
assistance.
WHERE  TO  INSTALL:    Before  installing  your  Smoke/CO 
detector, it is important to choose the best locations in your 
home.    Placement  will  affect  how  well  the  device  performs 
and how well residents hear the alarm siren if it sounds.  For 
maximum  protection,  Life  Alert  recommends  a  Smoke/CO 
detector be installed on each level of a multi-level home, 
including  every  bedroom,  hallways,  finished  attics  and 
basements.    Install  a  detector  in  every  room  where 
someone sleeps with the door closed.  A closed door may 
prevent a detector not located in that room from waking the 
occupant.  For bedrooms, hallways, or large rooms greater 
than 30 feet (9.1 m) in length, install detectors at both ends 
of  the  room  or  hallway.    For  additional  protection,  place 
additional  Smoke/CO  detectors  between  5  and  20  feet 
from  potential  sources  of  CO,  such  as  a  furnace,  water 
heater or fireplace.   
 If you only have one detector, ensure it is placed in the 
hallway outside of the  main sleeping area, or in the main  
bedroom.    Verify  that  the  detector  can  be  heard  in  all 
sleeping areas.  
Do not install the Smoke/CO detector in garages, kitchens, 
furnace rooms, fireplaces, bathrooms, or unfinished attics.  
Keep  the  device  at  least  5  feet  (1.5  m)  away  from  any 
fuel-burning equipment.  Keep the device at least 3 feet 
(0.9  m)  away  from  the  following:  a  door  to  a  kitchen  or 
bathroom (that contains a tub or shower), air conditioners 
or  forced  air  supply  ducts  used  for  heating  or  cooling, 
ceiling or whole house ventilating fans, or other high air 
flow areas.  Keep the detector away from drapes or other 
objects that may block airflow to the sensors.  Do not place 
the device in the direct sunlight or near doors and windows 
that open up to the outside.  Install the detector at least 1 
foot (0.3 m) away from fluorescent lights.  Do not install in 
areas  where  the  temperature  is  colder  than  40  degrees 
Fahrenheit  (4.4  Celsius)  or  hotter  than  100  degrees 
Fahrenheit  (37.8  Celsius)  as  extreme  temperature  will 
affect  the  sensitivity  of  the  Smoke/CO  detector.    Do  not 
install in areas where the relative humidity is greater than 
85%.  Avoid excessively dirty, dusty, or greasy areas.  Dirt, 
dust, grease, or household chemicals can contaminate the 
device’s sensors, causing it to not operate properly.  Make 
sure to keep the detector away from any insect infested 
areas.
CEILING OR WALL INSTALLATION: Ceiling mounting is 
preferred in an ordinary residential environment.  Smoke, 
Figure 4.   Recommended Locations on Sloped Ceilings
Figure 6.   Detector Rear Side and 
Proper Battery Placement
Figure 8.  General View of Smoke/CO Detector
Figure 3.   
Recommended 
Locations on 
Ceiling and Wall
Figure 5.   Separating the 
Detector from the Bracket
SMOKE TEST BUTTON
LED INDICATOR
CO TEST BUTTON
Figure 7.  Mounting the Smoke/CO detector
Figure 1.  Locations 
for Placing Smoke/CO 
Detectors in a Single-
Floor Residence
Figure 2.  Locations 
for Placing Smoke/CO 
Detectors in a Multi-
Floor Residence
GENERAL INFORMATION
FEATURES
FEATURES
WHERE TO INSTALL
WHERE NOT TO INSTALL
MOUNTING THE BRACKET
SLOPED CEILING INSTALLATION
CEILING OR WALL INSTALLATION
TESTING
INSTALLING THE BATTERIES
GENERAL MAINTENANCE
BATTERY
COMPARTMENTS