SHENZHEN IP-COM NETWORKS CO. LTD. AP345V2 ユーザーズマニュアル

ページ / 1
Know Your AP
Install the AP
Set Up Your WiFi Network
3.
  
2.
  
2
3
Position the bracket onto the celling and
mark screw holes on the celling with the 
marker.
Drill holes in the marked positions using 
hammer drill.
Knock the expansion bolts into the holes 
using the rubber hammer.
3
Use the screwdriver to drive screws into 
the expansion bolts so as to fasten the 
bracket.
Port / Button
Description
LAN
It is a 10/100 Mbps auto-negotiation port used to transmit data or supply PoE 
power for the AP using an Ethernet cable. PoE devices compliant with IEEE
802.3aforIEEE802.3atstandardcansupplypowertotheAP.
PWR
It is a DC power jack used to connect to the included power adapter.
RESET
It is used to reset the AP. 
Method to reset: When the SYS indicator blinks, hold the RESET button down 
for about 8 seconds. The AP is reset successfully when the SYS indicator gets 
solid on.
Insert the hooks of the AP into the slots 
of the bracket, and slide the AP to one 
side to make sure that the AP is fixed 
well in the bracket. 
LED indicator
Status
  Description
SYS
Solid on
   The system is starting. 
   If the indicator is still solid on after the AP finishes startup, it  
indicates that the system is faulty.
Blinking 
The AP is working properly.
Off
The AP is powered off or the LED indicator is disabled.
Scenario 1: Set up WiFi network without a management device for IP-COM AP
Scenario 3: Set up WiFi network with an IP-COM router that can manage APs
Tip:If you have more than one AP, connect one AP to your PoE switch and perform 
         steps  to  for it first. Then connect and configure other APs one by one.
1
Connect devices
Connect your AP to a PoE port of the PoE switch using an Ethernet cable.
Refer to the following figure for detailed connection.
After finishing connection, ensure that the AP's LED indicator blinks and 
the lower-right network icon on your computer is not displayed       . 
Configure the IP address of your computer(Example: Win7)
Right-click the network icon on the lower-right corner of your computer. 
Click Open Network and Sharing CenterLocal Area Connection, and then 
Properties. Double-click Internet Protocol Version 4 (TCP/IPv4), select 
Use the following IP address, set IP address to 192.168.0.x (x: 2 to 253. 
The IP address in this example is 192.168.0.10) and Subnet mask to 
255.255.255.0, and click OK.
Set WiFi name and WiFi password for the AP
Start a web browser on your computer, enter 192.168.0.254 in the address 
bar, and press Enter to log in the web UI of your AP. Click Quick Setup on 
the web UI, configure SSID (WiFi name), Security Mode (WPA2-PSK is 
recommended), Key for the 2.4 GHz WiFi network, and click Save. Then set 
Radio Band to 5 GHz, configure SSIDSecurity Mode and Key for it as 
well, and click Save.
4
Change the IP address of the AP 
Click Network>LAN Setup. Change the IP address of the AP to 
192.168.0.x (x: 2 to 253), and ensure that the new IP address has not 
been used in this network, then click Save. For example, you can set 
the new IP address of the first AP to 192.168.0.201, and the new IP 
address of the second AP to 192.168.0.202. 
Wait a moment for the settings to take effect. Now you can access the 
internet by connecting your wireless devices to the AP's WiFi network.
WiFi name: The SSID you set in step       .
WiFi password: The key you set in step        . 
Scenario 2: Set up WiFi network with an IP-COM AP Controller
1
Connect devices
Use Ethernet cables to connect APs to the PoE ports of the switch, and 
your computer to the IP-COM AP Controller (AC). Refer to the following 
figure for detailed connection.
2
ConfigureAPs
In order to configure your APs, start a web browser on your 
computer and log in to the web UI of the AC. Refer to your 
AC's user guide for detailed configuration instructions. 
FAQ
Tip:You may need a rubber hammer, a marker, a hammer drill, a drill bit, a screwdriver, 
         and a ladder for the installation. Please prepare them yourself.
Configure APs
In order to configure your APs, start a web browser on your 
computer and log in to the web UI of your router
Refer to the router's user guide for detailed configuration instructions. 
Note:PoE supply is used as an example in all the setup instructions below. 
3
3
2
Tip: If you cannot log in to the web UI of the AP, refer to Q1 in FAQ.
Q1: I cannot access the web UI of the AP after entering 192.168.0.254. 
         What should I do?
A1:
  Try the following solutions and log in again:
         
  
   Ensure that all your Ethernet cables are properly connected.
          If there is no AC or IP-COM router in the network, ensure that the IP address of your 
          computer has been set to 192.168.0.x (x: 2 to 253), and the IP address is not used by any 
          other devices in the same network. 
          Clear the cache of your web browser or replace the web browser.
          Disable the firewall of your computer or replace your computer.
          If two or more APs are connected in the network without an AC / IP-COM management 
          router, an IP address conflict may happen. You should leave only one AP in the network first 
          and set a new IP address 192.168.0.x (x: 2 to 253) for the AP. Then repeat this procedure to 
          change the IP addresses of the other APs. Meanwhile, make sure that the IP address of 
          your computer is in the same network segment with your APs' new IP addresses. Then try 
          logging in to the web UI of your APs using their new IP addresses.
If the AP has been managed by the AC or IP-COM router in the network, the AP's IP 
          address may be no longer 192.168.0.254. In that case, go to the web UI of the AC / router 
          to view the new IP address of the AP, and then log in to the AP's web UI using the new 
          IP address.
If the problem still persists, hold the RESET button down for 8 seconds to restore the AP 
          to factory settings, and then try logging in again.
Q2:  My AP controller (AC) cannot find my AP. What should I do?
A2:
  Check the following items:
          Ensure that all the devices in the network are connected well and the LED of the AP blinks.
          If VLANs have been set in your network, ensure that the AP belongs to the same VLAN as 
          that of your AC.
          Reboot your AP.
          Ensure that the firmware versions of your AP and AC are the latest firmware versions 
          available on www.ip-com.com.cn
Reset your AP. 
          Method to reset: When the SYS indicator blinks, hold down the RESET button for about 
          8 seconds. The AP is reset successfully when the SYS indicator gets solid on.
1
Connect devices
Use Ethernet cables to connect APs to the PoE ports of the switch, and 
your computer to the IP-COM router. Refer to the following figure for 
detailed connection.
Connect an Ethernet cable (CAT5 or better) to 
the LAN port of the AP. If you choose to power 
on the AP by DC supply, connect the PWR port 
of the AP using the power adapter included in 
the package.
IP-COM AP Controller
PoE switch 
Internet
Computer 
Router
Laptop
Smart phone
Tablet PC
AP
AP
AP
IP-COM Router 
(Supporting AP management)
Laptop
Smart phone
Tablet PC
PoE switch 
AP
Internet
Computer
Router
Uplink port LAN port    
WAN port
Uplink port
LAN port
WAN port
AP
AP
AP
Internet
LAN port
WAN port
Uplink port
Laptop
Smart phone
Tablet PC
Computer
PoE switch 
LAN port
6
1
2
4
RESET
5
RESET
System LED indicator
1.
  
LAN
PWR
RESET
RESET
11AC Dual Band Ceiling Access Point
Quick Installation Guide
If any item is incorrect, missing, or damaged, please keep the original package and contact the local reseller or 
distributor immediately.
*For more product or function details, please go to www.ip-com.com.cn to download the user guide.
Package Contents
 
Access point * 1
 Bracket * 1
Power adapter * 1
Quick installation guide * 1
 Mounting accessory (including sleeve anchors and screws) * 1
 
Slot
Hook
General
You can get IP settings assigned automatically if your network supports 
this capability. Otherwise,you need to ask your network administrator for
the appropriate IP settings.
Obtain an IP address automatically
Use the following IP address:
Obtain DNS  server address automatically
Use the following DNS server addresses:
Advanced
OK
Cancel
Default gateway:
Subnet mask:
IP address:
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit
Internet Protocol Version 4 (TCP/IPv4)Properties
255
255
255
0
192
0
10
168
CE Mark Warning
This is a Class B product. In a domestic environment, this product may cause radio interference, in 
which case the user may be required to take adequate measures.
Operations in the 5.15-5.25GHz band are restricted to indoor use only.
The mains plug is used as disconnect device; the disconnect device shall remain readily operable.
This equipment should be installed and operated with minimum distance 20cm between the 
device and your body.
NOTE: (1) The manufacturer is not responsible for any radio or TV interference caused by 
unauthorized modifications to this equipment. (2) To avoid unnecessary radiation interference, it is 
recommended to use a shielded RJ45 cable.
Declaration of Conformity
Hereby, IP-COM Networks Co., LTD. declares that the radio equipment type AP345 is in compliance 
with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: 
http://www.ip-com.com.cn/en/ce.html 
Operate Frequency: 
2.4 GHz: 2.412 GHz – 2.472 GHz           
5 GHz: 5.15 GHz – 5.25 GHz
EIRP Power (Max.): 
2.4 GHz: 19.95 dBm       
5 GHz: 22.9 dBm
Software Version: V1.0.0.4
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment 
off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is 
      connected.
— Consult the dealer or an experienced radio/TV technician for help.
The device is for indoor usage only. 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation.
Radiation Exposure Statement
This device complies with FCC radiation exposure limits set forth for an uncontrolled 
environment and it also complies with Part 15 of the FCC RF Rules. 
This equipment should be installed and operated with minimum distance 20cm between 
the radiator & your body. 
Caution: 
Any changes or modifications not expressly approved by the party responsible for 
compliance could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna 
or transmitter.
Operating frequency: 2412 – 2462 MHz, 5150 – 5250 MHz, 5725 – 5850 MHz
NOTE
(1) The manufacturer is not responsible for any radio or TV interference caused by 
unauthorized modifications to this equipment. (2) To avoid unnecessary radiation 
interference, it is recommended to use a shielded RJ45 cable.
Operating temperature: (-10 – 40) °C
Operating humidity: (10 – 90) % RH, (non-condensing)
Copyright
© 2018 IP-COM Networks Co., Ltd. All rights reserved.
This documentation (including pictures, images, and product specifications, etc.) is for reference only. 
To improve internal design, operational function, and/or reliability, IP-COM reserves the right to make 
changes to the products described in this document without obligation to notify any person or 
organization of such revisions or changes.
Technical Support
                    MAC AddressC8:3A:35:83:F1:B0
IP Address Type   Static IP Address
IPAddress
                    Subnet Mask255.255.255.0
Gateway192.168.0.1
PrimaryDNSServer8.8.8.8
SecondaryDNSServer     8.8.4.4                                              
                  Device Name Access Point
               Ethernet Mode    Auto-negotiation       10 Mbps Half Duplex
LANSetup
Status
Quick Setup
Network Settings
LAN Setup
DHCP Server
Wireless Settings
SNMP
Deployment
Tools
Administrator admin
Save
Restore
Help
Status
Quick Setup
Network
Wireless
SNMP
Deployment
Tools
       Radio Band    2.4 GHz
Working ModeAP Client + AP
                    SSID    
Security ModeWPA2-PSK
Encryption AlgorithmAESTKIPTKIP&AES
                      Key
Administrator admin
Quick Setup
Save
Restore
Help
Telephone: (86 755) 2765 3089            
Website: http://www.ip-com.com.cn             
E-mail:  info@ip-com.com.cn
Address Info: 
Room 101, Unit A, First Floor, Tower E3, No. 1001, Zhongshanyuan Road, 
Nanshan District, Shenzhen, China. 518052
                          
                             
Caution:
Adapter Model: BN036-A12012E/BN036-A12012B
Manufacture: SHENZHEN HEWEISHUN NETWORK TECHNOLOGY Co., LTD.
Input: 100-240 V AC, 50/60 Hz, 0.4 A
Output: 12 V          1.0 A
         : DC Voltage
      RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic equipment 
(WEEE). This means that this product must be handled pursuant to European directive 
2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling organization or to the retailer 
when he buys a new electrical or electronic equipment.
IP-COM router (Supporting AP management)
For EU/EFTA, this product can be used in the following countries: