SOYAL TECHNOLOGY CO. LTD. AR-661UGV2 ユーザーズマニュアル

ページ / 4
 
 
- 3 - 
V150819
 
AR-661UG (V2) User Manual
Stationary UHF RFID Reader
 
 
Wire Application 
Wire 
Color 
Description 
Power 0 
Black 
DC Power Jack   
Apply for the size in OD55mm*ID20mm*11mm(L) 
DC12V / 1.5A 
RS-485  
1 Orange-White 
RS-485 
(A+) 
2 Orange 
RS-485 
GND (WG) 
Blue-White 
GND for Wiegand Connection 
GND (RS-485) 
Blue 
GND for RS-485 Connection 
Wiegand 
5 Green-White Wiegand Data: 1 Input 
Green 
Wiegand Data: 0 Input 
DI 7 
Brown-White 
External control signal input 
H:3.3V / L:0V 
*If DI is not in use, please connect it with the blue 
or blue/white wire.
 
DO 8 
Brown 
Reader control signal output 
(For RS-485 Connection Only) 
 
 
Notice of Installation 
 
1.  Secure the AR-661UG(V2) RFID reader on a column, pedestal, wall, or beam at least 150cm 
above ground and leave space for adjusting the up and down and left and right angles of the 
reader. 
 
2.  Check the antenna pattern and adjust the support angle for the reader to face the position the tag 
will pass through. 
 
3.  Although the ideal sensing range of AR-661UG(V2) is over 10m, the actual sensing range varies 
due to weather (raining, fog, sunny) and installation method (horizontal, inclining). 
 
 
Installation 
 
Step 1: Use a screwdriver to screw the 
L-Bracket on the backside of UHF reader 
Step 2: Take off the nuts and 
gaskets from 
U-bracket. Set the U-bracket into any cylinder at 
the site. Gradually attach the Fixed Bracket and 
Step 1 to U-Bracket and fixed by the nuts and 
gasket.