Microgate WIT005 ユーザーズマニュアル

ページ / 125
 
 
  
 
Microgate Srl 
 
P. 104 / 125 
5.4.1.2  F
REQUENCY
 
To prevent frequency collisions with other Witty Kits on the field, it is possible to change the transmission 
channel (of both the timer and photocells, which must of course have the same channel). 
Put the n photocells that must be set into 'configuration mode': turn off the photocells and then press and 
hold the on/off button for 5 seconds (see chap. 2.2.2). When all photocells have a red blinking status LED, on 
the Witty timer enter the channel number using the numerical keypad (from 1 to 8) and press Save (F1).  
The photocells, which have just received the command, emit a two-tone beep, restart and are turned on in 
normal  mode.  Use  the  Verify  Signal  function  (chap.  5.4.1.1)  to  ensure  that  the  channels  have  been  set 
correctly. 
The  “Reset  Default”  (F2)  button  resets  the  initial  photocell  conditions,  i.e.  Mode=Normal  and 
RadioPower=Normal, Activation Mode =Normally Open (see the following chapter; activation can be changed 
only using the Witty Manager software). 
 
The same applies to Witty·SEM e Witty·RFID accessories.