10.0.0.0/8 [1] auto-summary
10.0.0.0/16 [1] directly connected, vlan1
50.0.0.0/8 [16] via 10.0.0.1, vlan1
60.0.0.0/8 [16] via 10.0.0.1, vlan1
70.0.0.0/8 [16] via 10.0.0.1, vlan1
80.0.0.0/8 [16] via 10.0.0.1, vlan1
7. View the RIP route entries for the redistributed static routes are deleted
from the IP routing table.
UltOs# show ip route
C 10.0.0.0/16 is directly connected, vlan1
C 30.2.2.0/24 is directly connected, vlan3
4.5.9
Configuring Default-metric
Refer the Section 4.3 for configuration guidelines and Figure 4-1 for the
Setup. The prerequisite configuration needs to be done in the switches
(FDN40-1 and FDN40-2) before configuring RIP.
Setup. The prerequisite configuration needs to be done in the switches
(FDN40-1 and FDN40-2) before configuring RIP.
4.5.9.1
CLI Configuration
1. Execute the following commands in the switch FDN40-1 to configure the
default-metric.
Enter the Global Configuration mode.
UltOs# configure terminal
Enable RIP globally in the switch FDN40-1.
UltOs(config)# router rip
Enable RIP over the interface vlan 1 (IP address 10.0.0.1/16).
UltOs(config-router)# network 10.0.0.1
Configure default-metric for redistributed routes in the RIP domain.
UltOs(config-router)# default-metric 10
Configure redistribution of static routes into RIP domain.
UltOs(config-router)# redistribute static
Exit from the router configuration mode.
UltOs(config-router)# end
4.5.9.2
WEB Configuration
RIP default metric can be configured through WEB interface using the RRD
RIP Configuration screen. For screenshot, refer section 4.5.8.2.
RIP Configuration screen. For screenshot, refer section 4.5.8.2.
4.5.9.3
Sample Configuration to Test Default-metric
Refer the Section 4.3 for configuration guidelines and Figure 4-1 for the
Setup. The prerequisite configuration needs to be done in the switches
(FDN40-1 and FDN40-2) before configuring RIP.
Setup. The prerequisite configuration needs to be done in the switches
(FDN40-1 and FDN40-2) before configuring RIP.