Pre-Installation Instructions
1.  Prior to installing the lock into position, ensure the programming card and user cards/fobs have been initialized.
2.  Test card and lock to ensure proximity reader will read through the material that the lock is to be installed on.
3.  Cards/Fobs can read through as much as 1” (25mm) of non-metallic materials.
4.  DO NOT INSTALL MULTIPLE LOCKS OR EXTERNAL READERS IN CLOSE PROXIMITY (Fig. 6).
5.  Ensure that lock body and catch body do not contact when latch engages to ensure proper operation
Initializing the Lock
1.  Press the programming button 
on the back of the lock (Fig. 1).
2.  Lock will make a rapid 
beeping sound. Present the 
programming card to lock 
within three seconds.
3.  Two short tones indicate the 
programming card has been 
initialized.
4.  Multiple locks can be 
programmed using the same 
programming card.
Adding User Cards or 
Fobs
1.  Present the programming card to lock.
2.  Lock will make a rapid beeping sound. Present a user card/fob to the 
lock within three seconds.
3.  Two tones will indicate that the user card/fob has been accepted
4.  Lock can now be opened with this card/fob.
5.  Additional cards/fobs can be added by repeating steps 1–4.
Deleting a User Card/Fob
1.  Present the programming card to the lock.
2.  Lock will make a rapid beeping sound. Present user card/fob to the 
lock within three seconds.
3.  Four rapid tones indicated the card/fob has been successfully 
removed.
If user card/fobs have been lost all users will need to deleted and re-
enrolled.
Deleting All User Cards/Fobs
1.  Present programming card to lock 16 consecutive times.
2.  Sixteen beeps will sound followed by one long tone.
3.  All user cards/fobs have been deleted.
Alarm Feature
 
(Optional Alarm Pin must be used)
1.  When the alarm feature is enabled the lock will detect if the door is 
left ajar or forced open.
2.  When the door is left ajar for more than 30 seconds the alarm will 
beep for approx. 5 seconds. After the 5 seconds it will increase the 
volume of sound. Closing the door or presenting a valid user card will 
silence the alarm.
3.  If the door is forced open the sounder will sound at full volume 
immediately. To silence the alarm a valid user card must be 
presented to the lock.
FCC Regulatory Statements
This device complies with Part 15 of the FCC Rules. Operation is subject 
to the following two conditions: 
(1) This device may not cause harmful interference. 
(2) This device must accept any interference received, including 
interference that may cause undesired operation. 
This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to part 15 of the Federal Communication 
Commission (FCC) rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential 
installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment causes harmful interference 
to radio or television reception, which can be determined by turning 
the equipment off and on, the user is encouraged to try to correct the 
interference by doing one or more of the following measures: 
•Reorient or relocate the receiving antenna. 
•Increase the separation between the equipment and receiver. 
•Connect the equipment into an outlet on a circuit different from that to 
which the receiver is connected. 
•Consult the dealer or an experienced radio/TV technician for help.
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES 
OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY 
RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID 
THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
Fig. 1
Programming 
Button
       © 2017 RutheRfoRd CoNtRolS INt’l | dormakaba Group
        www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com