Alcatel-Lucent Deutschland AG CMCOB41AC2X6 ユーザーズマニュアル

ページ / 126
SS-1 Venue survey checklist
Venue address
Venue
Name
Street address
City, State
Venue details
The following items must be completed prior to the installation of site equipment. Circle
the correct letter for the corresponding item descriptions.
Item
#
Description
Yes
(Y)
No
(N)
N/A
Comments
1.
The altitude of the venue relative to sea
level is between −197 ft and +5900 ft.
Y
N
N/A
2.
Ambient temperatures at the venue are
expected to remain above −40 °F (-40 °C)
and below 131°F (55 °C).
Y
N
N/A
3.
Temperature swings at the venue are
expected to be always less than 86 °F (30
°C).
Y
N
N/A
4.
Humidity at the venue is expected to be
always 5% or greater.
Y
N
N/A
5.
RF spectrum analysis has been performed
in the venue at various times of day on
various days of the week and has shown
no activity that is likely to cause
interference with the transmission or
reception of the Metro Cells.
Y
N
N/A
6.
The power factor of 0.92 meets the
approval of the company that supplies
power to the venue.
Y
N
N/A
7.
Dust at the venue is expected to be below
the limit for a NEMA Type 4 enclosure.
Y
N
N/A
Site survey checklists
SS-1 Venue survey checklist
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
A-2
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
9764 CMCO B41 2x6W
3MN-02026-0001-RJZZA
Issue 0.01
March 2015
D
R
AFT
D
R
AFT