4.
Calibration
1. Turn on the printer by pressing the left hand power button.
2. Allow the machine to boot up to the home screen, as shown below.
3. Open the door and remove the two cartridges, the grey MUM and the yellow ITM.
The solvent cartridge is removed by twisting clockwise (seen from above). The ink
cartridge is removed by twisting anti-clockwise (seen from above). The cartridges will
self-seal when removed.
The ITM requires the yellow latches to be lifted before the unit can be pulled out of the
machine.
The MUM has a retaining thumb screw which should be removed first. Withdraw the
MUM and remove the plastic pipe. This is removed by pushing in the black retaining
collar into the MUM and pulling out the pipe.