HP Intelligent Power
Distribution Units
 (iPDU)
iPDU Core Units
HP 4.9kVA 24A Single Phase Core Intelligent Modular Power Distribution Unit
AF520A
HP 8.6kVA 24A Three Phase Core Intelligent Modular Power Distribution Unit
AF522A
HP 11.4kVA 16A 415V Three Phase L22-20 Core Intelligent Power Distribution Unit
AF900A
HP 17.3kVA 24A 415V Three Phase L22-30 Core Intelligent Power Distribution Unit
AF902A
HP 17.3kVA 24A 415V Three Phase IEC309 Core Intelligent Power Distribution Unit
AF901A
HP 17.3kVA 48A 208V Three Phase 12 Outlet Core NA/JP Intelligent Power Distribution
Unit
AF535A
HP 17.3kVA 24A 415V Three Phase 12 Outlet Core NA/JP Intelligent Power Distribution
Unit
AF537A
iPDU Extension Bars
 
HP 5xC13 Intelligent PDU Extension Bar G2 Kit
AF547A
HP 5xC13 Outlets Power and UID LEDs Pair Standard Extension Bar
AF528A
NOTE: Please see the QuickSpecs for Technical Specifications and additional
information:
 
HP Rack Series
HP Rack 10000 G2 Series (Carbon/Graphite Metallic)
HP 10642 G2 1200mm deep Shock Rack
AF092A
HP 10647 G2 1200mm deep Shock Rack
AF094A
NOTE: It is mandatory to use a shock pallet when shipping racks with equipment
installed.
NOTE: Please see the QuickSpecs for Technical Specifications and additional
information:
NOTE: For additional information regarding Rack Cabinets, please see the following
URL: 
.
 
NOTE: The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks
provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded
with servers using the latest processors.
CAUTION: If a third-party rack is used, observe the following additional requirements to
ensure adequate airflow and to prevent damage to the equipment: Front and rear
doors: If your 42U server rack includes closing front and rear doors, you must allow 830
square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit
adequate airflow (equivalent to the required 64 percent open area for ventilation). Side:
The clearance between the installed rack component and the side panels of the rack
must be a minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in
the rack. This arrangement ensures proper airflow. Using a rack without blanking
panels results in improper cooling that can lead to thermal damage.
 
NOTE: Quick deploy rail system provides tool-free support for racks with square or
round mounting holes (including Compaq/HP 7000, 9000, 10000 G2 and HP series), with
an adjustment range of 24" - 36". The ambidextrous cable management arm can be
mounted on either the left or right side for improved cable management.
 