HP BL465c G7 663063-S01 ユーザーズマニュアル

製品コード
663063-S01
ページ / 44
System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions
(H x W x D)
7.154 x 2.19 x 20.058 in (18.17 x 5.56 x 50.95 cm)
Weight
Weight
Weight
Weight
(approximate)
Maximum
(all hard drives, DIMMs,
and processors installed)
13.9 lb (6.3 kg)
Minimum
(no hard drives, two
DIMMs, and one
processor installed)
9.8 lb (4.45 kg)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
For power specifications including Input Requirements, BTU Rating, and
Power Supply Output, please see the HP BladeSystem c-Class Enclosures
QuickSpecs located at URL:
HP BladeSystem c3000 Enclosure QuickSpecs:
HP BladeSystem c7000 Enclosure QuickSpecs:
To review typical system power ratings use the HP Power Advisor which is
available via the online tool located at: 
NOTE:
NOTE:
NOTE:
NOTE: For optimal cooling and system performance the BL465c G7
requires the c7000 enclosure to be configured with 10 fans and the c3000
enclosure to be configured with 6 fans.
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be reduced if
operating with a fan fault, or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
Altitude
Altitude
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Non-operating
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
For acoustic noise specifications, please see the HP BladeSystem c-Class
Enclosures QuickSpecs located at URL:
QuickSpecs
HP ProLiant BL465c Generation 7 (G7) Server Blade
HP ProLiant BL465c Generation 7 (G7) Server Blade
HP ProLiant BL465c Generation 7 (G7) Server Blade
HP ProLiant BL465c Generation 7 (G7) Server Blade
Technical Specifications
DA - 13654   North America — Version 20 — February 13, 2012