Installation and Use
Page 58
USERS
ADMIN
Alan
Jim
Sue
Test
PASSWORDS
password
letmein
hello
logmein
Test
COMPUTERS
PORT
Admin PC
2103
1
1
1
1
Alan's System
2102
1
1
1
Comms Server
3
1
1
Comms PC
4
1
1
1
1
Gateway 1
8
1
Gateway 2
5
1
Test System
15
1
1
Web Browser
9
1
1
1
To restore the saved / edited menu and configuration settings:
1. Connect the serial port on the rear of the AdderView MATRIX MP to a serial
COM port on your computer using the serial cable supplied with the AdderView.
2. Copy the program AVMWRITE and AVMDATA.CSV into the same directory on
the PC that is connected to the AdderView’s serial port.
3. Run the program AVMWRITE.EXE and follow the instructions given by the
program.
4. Make sure that you are logged onto the AdderView as the ADMIN user. From the
main selection screen press F1 for 
More Menus. In the Configuration Menu
select 
Functions. In the Functions menu select Read Data from RS232 port.
5. The AdderView should then receive the configuration data to your computer and
load the new menu names and access rights into the menu.
4.20 Switching channels by sending RS232 data
You can switch the AdderView MATRIX MP remotely by sending RS232 data to the
serial communications port (located on the rear panel adjacent to the power
connectors). All data should be sent using the following RS232 protocol.
Baud: 19200, bits: 8, stopbits: 1, parity:none