High UPS reliability
• Total microprocessor control
• Static and manual bypass without 
interruption
• Features guaranteed up to 40° C (the 
components are designed to work at 
high temperatures and thus are subject 
to less stress at normal temperatures)
Operation selection
The operating mode may be programmed 
using software or manually via the mimic 
panel.
• On-line
• ECO Mode, to increase output (up to 
to 98%), allows for selection of Line 
Interactive technology (VI) to power low 
priority loads from the mains supply. 
• Smart Active, the UPS automatically 
decides upon the operating mode 
(VI or VFI) based on the quality of the 
network.
• Back-up, the UPS can be selected to 
function only when mains power fails 
(emergency mode only)
• Frequency converter (50 or 60 Hz).
High quality output voltage
• Even with non-linear loads 
(loads with a crest factor of up to 3:1)
• High short circuit current on Bypass
• High overload capacity 150% by 
inverter (even with mains failure).
• Filtered, stabilised and reliable voltage 
(double conversion On-line technology 
(VFI compliant with IEC 62040-3) 
with filters for the suppression of 
atmospheric disturbances.
• Power factor correction: UPS input 
power factor, close to 1 and sinewave 
current absorption
Simplified Installation
• UPS can be installed on single-phase or 
three-phase distribution network
• Output terminal board + 2 IEC sockets 
for powering local utilities (computers, 
modems, etc.)
• Simplified positioning (built-in wheels).
High battery reliability
• Automatic and manual battery test
• Reduced ripple component (detrimental 
to the batteries) thanks to the “LRCD” 
system (Low Ripple Current Discharge)
• Unlimited extendible runtime via 
dedicated modular design Battery 
Boxes
• The batteries are not activated during 
mains failure of <40 ms (high hold up 
time) or when there are variations in 
input voltage (from 84V to 276V).
EnergyShare
The presence of two 10A  configurable  
IEC output sockets, allows for runtime 
optimisation, programming the switch-
off of low priority loads; alternatively, 
emergency only loads,  normally not 
powered when the mains is present, can 
be activated.
Low impact on mains network
• Sinusoidal absorption of input current 
on single-phase/single-phase series.
Other features
• Advanced diagnostics: status, 
measurements, alarms available on 
custom LDC display
• Low noise (<40dBA) for installation 
in any environment thanks to PWM 
digitally-controlled ventilation, 
depending on the load applied and on 
the use of a high frequency switching 
inverter (>20kHz, value greater than the 
audible range)
• Auto restart (automatic when mains 
supply is restored, programmable via 
software or mimic panel)
• Emergency back-up function, the UPS 
can be selected to function only when 
mains power fails (emergency lighting 
only)
• Back feed protection standard: to 
prevent energy from being feed back 
into the main supply
• UPS digital updating (flash upgradable)
Advanced communication
• Compatible with Riello UPS 
TeleNetGuard teleassistance
• Advanced multi-platform 
communication for all operating 
systems and network environments: 
PowerShield
3
 supervision and 
shutdown software for Windows 
operating systems 7, 2003, Vista, 2003, 
XP, Linux, Mac OS X, Sun Solaris, 
Linux, Novell and other Unix operating 
systems.
• RS232 serial port
• Plug and Play function
• Slot for installation of communications 
boards.