Intel R1304BTLSHBN8 ユーザーズマニュアル
Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
Appendix B: Integrated BMC Sensor Tables
Revision 2.1
45
Intel order number G17455-005
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm Stand-
by
Power Supply 1
Fan Tachometer 1
(PS1 Fan Tach 1)
Fan Tachometer 1
(PS1 Fan Tach 1)
A0h
Chassis-
specific
Fan
04h
Threshold
01h
–
–
–
Analog
–
–
–
Power Supply 1
Fan Tachometer 2
(PS1 Fan Tach 2)
Fan Tachometer 2
(PS1 Fan Tach 2)
A1h
Chassis-
specific
Fan
04h
Threshold
01h
–
–
–
Analog
–
–
–
Power Supply 2
Fan Tachometer 1
(PS2 Fan Tach 1)
Fan Tachometer 1
(PS2 Fan Tach 1)
A4h
Chassis-
specific
Fan
04h
Threshold
01h
–
–
–
Analog
–
–
–
Power Supply 2
Fan Tachometer 2
(PS2 Fan Tach 2)
Fan Tachometer 2
(PS2 Fan Tach 2)
A5h
Chassis-
specific
Fan
04h
Threshold
01h
–
–
–
Analog
–
–
–
Processor DIMM
Aggregate Thermal
Margin
Aggregate Thermal
Margin
(Mem P1 Thrm
Mrgn)
Mrgn)
B0h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
Degraded
c = Non-
fatal
fatal
As and
De
Analog
R, T
A
–
Processor DIMM
Thermal Trip
(Mem P1 Thrm
Trip)
Thermal Trip
(Mem P1 Thrm
Trip)
C0h
All
Temperature
01h
Digital
Discrete
03h
01
– State
Asserted
Fatal
As and
De
–
Trig
Offset
M
X
Baseboard +12V
(BB +12.0V)
D0h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
Degraded
c = Non-
fatal
fatal
As and
De
Analog
R, T
A
–
Baseboard +5V
(BB +5.0V)
D1h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
Degraded
c = Non-
fatal
fatal
As and
De
Analog
R, T
A
–