Intel S2600JF BBS2600JF ユーザーズマニュアル

製品コード
BBS2600JF
ページ / 194
Platform Management Functional Overview 
Intel®
 
Server Board S2600JF TPS 
 
 
Revision 1.3 
Intel order number G31608-004 
48 
The three possible IPv6 IP Address Sources for configuring the BMC are: 
  Static (Manual): The IP, Prefix, and Gateway parameters are manually configured by 
the user. The BMC ignores any Router Advertisement messages received over the 
network. 
  DHCPv6: The IP comes from running a DHCPv6 client on the BMC and receiving the IP 
from a DHCPv6 server somewhere on the network. The Prefix and Gateway are 
configured by Router Advertisements from the local router. The IP, Prefix, and Gateway 
are read-only parameters to the BMC user in this mode. 
  Stateless auto-config: The Prefix and Gateway are configured by the router through 
Router Advertisements. The BMC derives its IP in two parts: the upper network portion 
comes from the router and the lower unique portion comes from the BMC’s channel 
MAC address. The 6-byte MAC address is converted into an 8-byte value per the EUI-
64* standard. For example, a MAC value of 00:15:17:FE:2F:62 converts into a EUI-64 
value of 215:17ff:fefe:2f62. If the BMC receives a Router Advertisement from a router at 
IP 1:2:3:4::1 with a prefix of 64, it would then generate for itself an IP of 
1:2:3:4:215:17ff:fefe:2f62. The IP, Prefix, and Gateway are read-only parameters to the 
BMC user in this mode. 
 
IPv6 can be used with the BMC’s Web Console, JViewer (remote KVM and Media), and 
Systems Management Architecture for Server Hardware 
– Command Line Protocol 
(SMASH-CLP) interface (ssh). There is no standard yet on how IPMI RMCP or RMCP+ 
should operate over IPv6 so that is not currently supported. 
4.6.5.1 
LAN Failover 
The BMC FW provides a LAN failover capability such that the failure of the system HW 
associated with one LAN link will result in traffic being rerouted to an alternate link. This 
functionality is configurable through 
IPMI methods as well as through the BMC’s Embedded UI, 
allowing for user to specify the physical LAN links constitute the redundant network paths or 
physical LAN links constitute different network paths. BMC will support 
“only-all-or-nothing” 
approach 
– that is, all interfaces bonded together, or none are bonded together. 
The LAN Failover feature applies only to BMC LAN traffic. It bonds all available Ethernet 
devices but only one is active at a time. When enabled, if 
the active connection’s leash is lost, 
one of the secondary connections is automatically configured so that it has the same IP 
address. Traffic immediately resumes on the new active connection. 
The LAN Failover enable/disable command may be sent at any time. After it has been enabled, 
standard IPMI commands for setting channel configuration that specify a LAN channel other 
than the first will return an error code. 
4.7  System Event Log (SEL) 
The BMC implements the system event log as specified in the Intelligent Platform Management 
Interface Specification, Version 2.0. 
The SEL is accessible regardless of the system power state 
through the BMC's in-band and out-of-band interfaces. 
The BMC allocates 65,502 bytes (approx. 64 KB) of non-volatile storage space to store system 
events. The SEL timestamps may not be in order. Up to 3,639 SEL records can be stored at a