Intel R1304BTLSFANR ユーザーズマニュアル

ページ / 67
Appendix B: Integrated BMC Sensor Tables
                                                                               
Intel
®
 Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
 
46 
 
 
 
Revision 2.1 
Intel order number G17455-005 
Full Sensor Name 
(Sensor name in SDR) 
Sensor 
Platform 
Applicability 
Sensor Type 
Event/Reading 
Type 
Event Offset 
Triggers 
Contrib. To 
System 
Status 
Assert/De-
assert 
Readable
 
Value/Offsets 
Event 
Data 
Rearm  Stand-
by 
Baseboard +3.3V 
(BB +3.3V) 
D2h 
All 
Voltage 
02h 
Threshold 
01h 
[u,l] [c,nc] 
nc = 
Degraded 
c = Non-
fatal 
As and 
De 
Analog 
R, T 
– 
Baseboard +5V 
Stand-by 
(BB +5.0V STBY) 
D3h 
All 
Voltage 
02h 
Threshold 
01h 
[u,l] [c,nc] 
nc = 
Degraded 
c = Non-
fatal 
As and 
De 
Analog 
R, T 
Baseboard +3.3V 
Auxiliary 
(BB +3.3V AUX) 
D4h 
All 
Voltage 
02h 
Threshold 
01h 
[u,l] [c,nc] 
nc = 
Degraded 
c = Non-
fatal 
As and 
De 
Analog 
R, T 
Baseboard +1.2V 
Processor Vccp 
(BB P1 Vccp) 
D6h 
All 
Voltage 
02h 
Threshold 
01h 
[u,l] [c,nc] 
nc = 
Degraded 
c = Non-
fatal 
As and 
De 
Analog 
R, T 
– 
Baseboard +1.5V 
VDDQ 
(BB +1.5V P1 
MEM) 
D8h 
All 
Voltage 
02h 
Threshold 
01h 
[u,l] [c,nc] 
nc = 
Degraded 
c = Non-
fatal 
As and 
De 
Analog 
R, T 
– 
Baseboard CMOS 
Battery 
(BB +3.3V Vbat) 
DEh 
All 
Voltage 
02h 
Threshold 
01h 
[u,l] [c,nc] 
nc = 
Degraded 
c = Non-
fatal 
As and 
De 
Analog 
R, T 
–