Table 28. Passive SATA/SAS Backplane Power Connector Pin-out
Pin #
Signal Name
1
Ground
2
Ground
3
P5V
4
P5V
5
P12V
6
P12V
7
No Connection
8
P3V3
Table 29. Passive SATA/SAS Backplane Connector to Hard Drive Pin-out
Pin #
Signal Name
S1
Ground
S2
SAS_DRVxA_RX_P
S3
SAS_DRVxA_RX_N
S4
Ground
S5
SAS_DRVxA_TX_N
S6
SAS_DRVxA_TX_P
S7
Ground
P1
TP
P2
TP
P3
TP
P4
Ground
P5
Ground
P6
Ground
P7
P5V_DRVx_PRECHG
P8
P5V
P9
P5V
P10
Ground
P11
LED_DRVx_READY_N
P12
Ground
P13
P12V_DRVx_PRECHG
P14
P12V
P15
P12V
9.1.1
Hot-swap Drive Trays
You must mount each hard drive to a hot-swap drive tray, making insertion and extraction of the
drive from the system very simple. Each drive tray has its own dual-purpose latching
mechanism, which is used to both insert/extract drives from the system and lock the tray in
place. Each drive tray supports a light pipe providing a drive activity indicator, located on the
backplane, which is viewable from the front of the system.
drive from the system very simple. Each drive tray has its own dual-purpose latching
mechanism, which is used to both insert/extract drives from the system and lock the tray in
place. Each drive tray supports a light pipe providing a drive activity indicator, located on the
backplane, which is viewable from the front of the system.