IBM ServeRAID M5100 Series SSD Caching Enabler for Flex System 90Y4447 ユーザーズマニュアル

製品コード
90Y4447
ページ / 15
ServeRAID M5115 SAS/SATA Controller for IBM Flex System
3
Supported configurations
With the ServeRAID M5115, the compute node can support contain up to eight 1.8-inch solid-state drives. 
The M5115 attaches to the I/O adapter 1 connector and can be attached even if the Compute Node Fabric 
Connector is installed (used to route the embedded Ethernet controller to chassis bays 1 and 2). The 
ServeRAID M5115  cannot be installed if an adapter is installed in I/O adapter slot 1. 
The following figure shows where the ServeRAID M5115 is installed in an IBM Flex System compute node 
(x240 is shown as an example).
Figure 2. ServeRAID M5115 installed in the x240 Compute Node
The ServeRAID M5115 supports combinations of 2.5-inch drives and 1.8-inch solid state drives:
Up to two 2.5-inch drives only
Up to four 1.8-inch drives only
Up to two 2.5-inch drives, plus up to four 1.8-inch solid state drives
Up to eight 1.8-inch solid state drives
The ServeRAID M5115 provides an advanced RAID controller supporting RAID 0, 1, 10, 5, 50, and, 
optionally, 6 and 60. It includes 1 GB of cache, which can be backed up to flash memory when attached to 
the supercapacitor included with the optional ServeRAID M5100 Series Enablement Kit (90Y4342).