Intel R1304BTLSHBNR ユーザーズマニュアル
Appendix B: Integrated BMC Sensor Tables
Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
42
Revision 2.1
Intel order number G17455-005
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm Stand-
by
Baseboard
Temperature 3
(Inlet Temp)
Temperature 3
(Inlet Temp)
24h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
Degraded
c = Non-
fatal
fatal
As and
De
De
Analog
R, T
A
X
Hot-swap
Backplane
Temperature
(HSBP Temp)
Backplane
Temperature
(HSBP Temp)
29h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
Degraded
c = Non-
fatal
fatal
As and
De
De
Analog
R, T
A
X
Fan Tachometer
Sensors
Sensors
(Chassis specific
sensor names)
sensor names)
30h
–
34h
Chassis-
specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
Degraded
c = Non-
fatal2
fatal2
As and
De
Analog
R, T
M
–
Power Supply 1
Status
Status
(PS1 Status)
50h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00
– Presence
OK
As and
De
–
Trig
Offset
A
X
01
– Failure
Degraded
02
– Predictive
Failure
Degraded
03
– A/C lost
Degraded
06
–
Configuration
error
error
OK
Power Supply 2
Status
Status
(PS2 Status)
51h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00
– Presence
OK
As and
De
–
Trig
Offset
A
X
01
– Failure
Degraded
02
– Predictive
Failure
Degraded