Intel R1304BTLSHBNR ユーザーズマニュアル

ページ / 67
Appendix B: Integrated BMC Sensor Tables
                                                                               
Intel
®
 Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
 
42 
 
 
 
Revision 2.1 
Intel order number G17455-005 
Full Sensor Name 
(Sensor name in SDR) 
Sensor 
Platform 
Applicability 
Sensor Type 
Event/Reading 
Type 
Event Offset 
Triggers 
Contrib. To 
System 
Status 
Assert/De-
assert 
Readable
 
Value/Offsets 
Event 
Data 
Rearm  Stand-
by 
Baseboard 
Temperature 3 
 
(Inlet Temp) 
24h 
All 
Temperature 
01h 
Threshold 
01h 
[u,l] [c,nc] 
nc = 
Degraded 
c = Non-
fatal 
As and 
De 
Analog 
R, T 
Hot-swap 
Backplane 
Temperature 
 
(HSBP Temp) 
29h 
All 
Temperature 
01h 
Threshold 
01h 
[u,l] [c,nc] 
nc = 
Degraded 
c = Non-
fatal 
As and 
De 
Analog 
R, T 
Fan Tachometer 
Sensors 
(Chassis specific 
sensor names) 
30h
34h 
Chassis-
specific 
Fan 
04h 
Threshold 
01h 
[l] [c,nc] 
nc = 
Degraded 
c = Non-
fatal2 
As and 
De 
Analog 
R, T 
– 
Power Supply 1 
Status 
(PS1 Status) 
50h 
Chassis-
specific 
Power Supply 
08h 
Sensor 
Specific 
6Fh 
00 
– Presence 
OK 
As and 
De 
– 
Trig 
Offset 
01 
– Failure 
Degraded 
02 
– Predictive 
Failure 
Degraded 
03 
– A/C lost 
Degraded 
 
06 
– 
Configuration 
error 
OK 
Power Supply 2 
Status 
(PS2 Status) 
51h 
Chassis-
specific 
Power Supply 
08h 
Sensor 
Specific 
 
6Fh 
00 
– Presence 
OK 
As and 
De 
– 
Trig 
Offset 
01 
– Failure 
Degraded 
02 
– Predictive 
Failure 
Degraded